FEI_TPOAM_1.3.6.1.4.1.2011.5.25.119.9.2.41 hwL2vpnOamTunnelNonSupport

Trap Buffer Description

OAM for PW does not support the current public tunnel. (VcID=[VcID], VcType=[VcType], PeerAddr=[PeerAddr], OamType=[OamType])

OAM for PW does not support the current public tunnel.

This alarm is supported only on NetEngine 8000 F1A.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Error

Mnemonic Code

hwL2vpnOamTunnelNonSupport

Trap OID

1.3.6.1.4.1.2011.5.25.119.9.2.41

MIB

HUAWEI-L2VPN-OAM-MIB

Alarm ID

0x00F100a5

Alarm Name

hwL2vpnOamTunnelNonSupport

Alarm Type

qualityOfServiceAlarm

Raise or Clear

Raise

Match trap

FEI_TPOAM_1.3.6.1.4.1.2011.5.25.119.9.2.42 hwL2vpnOamTunnelNonSupportResumed

Trap Buffer Parameters

Parameter Description

VcID

Identifier of the layer 2 virtual circuit.

VcType

VC Type:

1-FR.

2-ATM_AAL5.

3-ATM_CELL_TRANSPORT.

4-VLAN.

5-ETHERNET.

6-HDLC.

7-PPP.

8-CEM.

9-ATM_CELL_VCC.

10-ATM_CELL_VPC.

11-IP_LAYER2_TRANSPORT.

12-ATM_ONE_TO_ONE_VCC_CELL_MODE.

13-ATM_ONE_TO_ONE_VPC_CELL_MODE.

14-ATM_AAL5_PDU_VCC_TRANSPORT.

15-FR_PORT.

16-CEP.

17-SAT_E1_OVER_PACKET.

18-SAT_T1_OVER_PACKET.

19-SAT_E3_OVER_PACKET.

20-SAT_T3_OVER_PACKET.

21-CESOPSN_BASIC_MODE.

22-TDMOIP_AAL1.

23-CESOPSN_TDM.

24-TDMOIP_AAL2.

25-FR_DLCI.

26-INTERWORKING.

27-VPLS.

64-IP_INTERWORKING.

PeerAddr

Peer IP address.

OamType

OAM Type:

1-MPLS OAM.

2-MPLS-TP OAM.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.119.9.1.3

hwL2vpnVcID

-

1.3.6.1.4.1.2011.5.25.119.9.1.4

hwL2vpnVcType

-

1.3.6.1.4.1.2011.5.25.119.9.1.5

hwL2vpnPeerAddr

-

1.3.6.1.4.1.2011.5.25.119.9.1.13

hwL2vpnOamType

-

Impact on the System

MPLS OAM or MPLS-TP OAM for PW will fail.

Possible Causes

MPLS OAM or MPLS-TP OAM does not support the current public tunnel of PW.

Procedure

1.Check the public tunnel type of PW.

If the tunnel type is TE, go to Step 3.

If the tunnel type is not TE, go to Step 2.

2.Change the public tunnel of PW to a TE tunnel.

If the alarm is cleared, go to Step 4.

If the alarm is not cleared, go to Step 3.

3.Collect alarm information, log information and configuration information, and then contact Huawei technical support personnel.

4.End.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
Next topic >