Notice NMS to clear active alarm.(AlarmClearedNum=[AlarmClearedNum],AlarmClearedSnList=[AlarmClearedSnList])
The NMS was notified to clear active alarms with specified sequence numbers.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Event |
Trap Severity |
Warning |
Mnemonic Code |
NOTICE_CLEAR_ALARM |
Trap OID |
1.3.6.1.4.1.2011.6.30.18.1.0.5 |
MIB |
HUAWEI-SNMP-NOTIFICATION-MIB |
Alarm ID |
This is an event trap and does not involve alarm ID. |
Alarm Name |
This is an event trap and does not involve alarm name. |
Alarm Type |
This is an event trap and does not involve alarm type. |
Raise or Clear |
This is an event trap and does not involve alarm generation or clearance. |
Match trap |
- |
Parameter | Description |
---|---|
AlarmClearedNum |
Number of active alarms to be cleared. |
AlarmClearedSnList |
List of the sequence numbers of active alarms to be cleared (the serial number are separated with comma). |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.6.30.17.15 |
hwAlarmClearedNum |
- |
1.3.6.1.4.1.2011.6.30.17.16 |
hwAlarmClearedSnList |
- |
According to IETF standards, after an active alarm is manually cleared or is cleared because of the deletion of the associated object, the clearance event cannot be reported to the NMS. In this case, the device sends an hwAlarmClearedReportTrap notification to notify the NMS to clear the alarm.