GRESM_1.3.6.1.4.1.2011.5.25.227.2.1.49 hwSidResourceThresholdExceed

Trap Buffer Description

SID resource usage exceeded a specified upper threshold.(SIDPoolID=[SIDPoolID],ResourceCurrentCount=[ResourceCurrentCount],ResourceTotalCount=[ResourceTotalCount],ResourceThresholdUpperLimit=[ResourceThresholdUpperLimit],ResourceThresholdLowerLimit=[ResourceThresholdLowerLimit])

SID resource usage exceeded a specified upper threshold.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Error

Mnemonic Code

hwSidResourceThresholdExceed

Trap OID

1.3.6.1.4.1.2011.5.25.227.2.1.49

MIB

HUAWEI-FWD-RES-TRAP-MIB

Alarm ID

0x00F102ad

Alarm Name

hwSidResourceThresholdExceed

Alarm Type

communicationsAlarm

Raise or Clear

Raise

Match trap

GRESM_1.3.6.1.4.1.2011.5.25.227.2.1.50 hwSidResourceThresholdExceedClear

Trap Buffer Parameters

Parameter Description

SIDPoolID

SID

ResourceCurrentCount

Number of used SIDs

ResourceTotalCount

Total number of SIDs

ResourceThresholdUpperLimit

Upper alarm threshold of the used SID resources

ResourceThresholdLowerLimit

Lower alarm threshold of the used SID resources

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.227.1.37

hwSIDPoolID

-

1.3.6.1.4.1.2011.5.25.227.1.38

hwSIDResourceCurrentCount

-

1.3.6.1.4.1.2011.5.25.227.1.39

hwSIDResourceTotalCount

-

1.3.6.1.4.1.2011.5.25.227.1.40

hwSIDResourceThresholdUpperLimit

-

1.3.6.1.4.1.2011.5.25.227.1.41

hwSIDResourceThresholdLowerLimit

-

Impact on the System

If the number of used SIDs reached a specific threshold, subsequent LSPs may fail to be established because all SIDs are used.

Possible Causes

SID resource usage reached a specified upper threshold.

Procedure

1. Run the display gresm sid-pool command to check the SID range. Check whether all services that use the SID resources are necessary. Delete some unwanted services that use SIDs and check whether the hwSidResourceThresholdExceedClear alarm is generated.

  • If the clear alarm is generated, go to Step 3.
  • If the clear alarm is not generated, go to Step 2.

2. Collect the trap information, log information, and configuration information, and then contact Huawei technical support personnel.

3. End.

Copyright © Huawei Technologies Co., Ltd.