The state of interface changed from suppress to unsuppress. (InterfaceName=[InterfaceName], SuppressState=[SuppressState])
| Trap Attribute | Description | 
|---|---|
| Alarm or Event | Alarm | 
| Trap Severity | Warning | 
| Mnemonic Code | hwIfDampInterfaceAlarm | 
| Trap OID | 1.3.6.1.4.1.2011.5.25.41.3.56 | 
| MIB | HUAWEI-IF-EXT-MIB | 
| Alarm ID | 0X0852201B | 
| Alarm Name | hwIfDampSuppress | 
| Alarm Type | communicationsAlarm | 
| Raise or Clear | Clear | 
| Match trap | 
| Parameter | Description | 
|---|---|
| InterfaceName | Interface name | 
| SuppressState | Interface suppression status: 
 | 
| VB OID | VB Name | VB Index | 
|---|---|---|
| 1.3.6.1.2.1.31.1.1.1.1 | ifName | ifIndex | 
| 1.3.6.1.4.1.2011.5.25.41.1.1.1.1.41 | hwIFExtDampStatus | hwIFExtIndex | 
Cause 1: The interface was added to a VS.Cause 2: The interface is offline.Cause 3: The suppression penalty value of the interface fell below the reuse value.Cause 4: The interface suppression function is disabled in system view or interface view.Cause 5: The damp-interface level configuration was changed.Cause 6: The damp-interface enable command was run in the system view, and the damp-interface ignore-global command was run in the interface view, which cleared related alarms on the interface.Cause 7: The damp-interface enable command was run in the system view, and the damp-interface enable command was run in the interface view, which cleared related alarms on the interface. The physical status suppression configurations on the interface takes precedence over the global configurations.Cause 8: The shutdown and undo shutdown commands were run in sequence on the local interface.