IGMP_1.3.6.1.4.1.2011.5.25.149.3.3.22 hwMgmdIfThresholdExceed

Trap Buffer Description

The number of IGMP or MLD entries on the interface reached the upper threshold. (AddressFamily=[AddressFamily], Ifindex=[IfIndex], CurrentCount=[CurrentCount], ThresholdCount=[ThresholdCount], Ifname=[IfName], InstanceName=[InstanceName])

The number of IGMP/MLD entries on the interface reached the upper threshold.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwMgmdIfThresholdExceed

Trap OID

1.3.6.1.4.1.2011.5.25.149.3.3.22

MIB

HUAWEI-MGMD-STD-MIB

Alarm ID

0x00F102d0

Alarm Name

hwMgmdIfThresholdExceed

Alarm Type

qualityOfServiceAlarm

Raise or Clear

Raise

Match trap

IGMP_1.3.6.1.4.1.2011.5.25.149.3.3.23 hwMgmdIfThresholdExceedClear

Trap Buffer Parameters

Parameter Description

AddressFamily

Address family:

  • 1: IPv4 family.
  • 2: IPv6 family.

IfIndex

interface index.

CurrentCount

Number of IGMP/MLD entries on the current interface. The IGMP/MLD entries that are newly added are not included.

ThresholdCount

Threshold at which the alarm is generated .

IfName

Name of the interface.

InstanceName

Instance of which the number of created (S, G) entries on the device reaches the specified limit.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.149.3.2.17

hwMgmdNotificationAddressType

-

1.3.6.1.4.1.2011.5.25.149.3.2.33

hwMgmdThresholdInterfaceIfIndex

-

1.3.6.1.4.1.2011.5.25.149.3.2.31

hwMgmdGmpIfCurrentCount

-

1.3.6.1.4.1.2011.5.25.149.3.2.32

hwMgmdGmpIfThreshold

-

1.3.6.1.4.1.2011.5.25.149.3.2.12

hwMgmdGmpInterfaceName

-

1.3.6.1.4.1.2011.5.25.149.3.2.16

hwMgmdInstanceName

-

Impact on the System

When the alarm is generated, new entries can still be created, but the specified limit may be reached.

Possible Causes

  • Cause 1: Entry create
  • Cause 2: Configuration change

Procedure

  • Cause 1: Entry create

    1. Run the display igmp interface command to check whether the value of igmp access-limit is set to a small number.

    • If the value of igmp access-limit is set to a small number, go to Step 2.
    • If the value of igmp access-limit is not set to a small number, go to Step 3.

    2. Run the igmp access-limit command to adjust the entry limit and check whether the fault is rectified.

    • If the fault is rectified, go to Step 4.
    • If the fault is not rectified, go to Step 3.

    3. Collect alarm information and configuration information, and then contact technical support personnel.

    4. End.

  • Cause 2: Configuration change

    The same as Cause 1.