The one-way delay of IPFPM test instance exceeded the upper threshold in continuous five test intervals. (TestInstanceId=[InstanceId], AchId=[AchId], IpfpmMcpSeqNoHigh=[SeqNoHigh], IpfpmMcpSeqNoLow=[SeqNoLow], FlowType=[FlowType], ForwardOneDelay=[ForDelayValue], BackwardOneDelay=[BackDelayValue], InstDesc=[InstDesc])
The one-way delay of an IP FPM instance exceeded the upper threshold over five consecutive statistical periods.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Critical |
Mnemonic Code |
hwIpfpmOneDelayExceed |
Trap OID |
1.3.6.1.4.1.2011.5.25.316.3.3 |
MIB |
HUAWEI-IPFPM-MIB |
Alarm ID |
0x09d72005 |
Alarm Name |
hwIpfpmOneDelayExceed |
Alarm Type |
qualityOfServiceAlarm |
Raise or Clear |
Raise |
Match trap |
Parameter | Description |
---|---|
InstanceId |
IP FPM instance ID |
AchId |
Atomic closed hop ID |
SeqNoHigh |
32 most significant bits of the statistical period ID |
SeqNoLow |
32 least significant bits of the statistical period ID |
FlowType |
Target flow type |
ForDelayValue |
One-way delay for the forward target flow |
BackDelayValue |
One-way delay for the backward target flow |
InstDesc |
Specify description of test instance |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.316.1.1.7.1.2 |
hwIpfpmMcpFlowType |
hwIpfpmMcpInstId hwIpfpmMcpAchId |
1.3.6.1.4.1.2011.5.25.316.1.2.5.1.2 |
hwIpfpmMcpForwardOneDelay |
hwIpfpmMcpInstId hwIpfpmMcpAchId hwIpfpmMcpSeqNoHigh hwIpfpmMcpSeqNoLow |
1.3.6.1.4.1.2011.5.25.316.1.2.5.1.4 |
hwIpfpmMcpBackwardOneDelay |
hwIpfpmMcpInstId hwIpfpmMcpAchId hwIpfpmMcpSeqNoHigh hwIpfpmMcpSeqNoLow |
1.3.6.1.4.1.2011.5.25.316.1.1.5.1.2 |
hwIpfpmMcpInstDesc |
hwIpfpmMcpInstId |
1. Check whether abnormal traffic existed on the network when the trap was generated.
2. Check whether the abnormal traffic was caused by misoperations.
3. Delete the misoperation configurations and check whether the trap persists.
4. Check whether the link status was stable when the trap was generated.
5. Check the problem that caused the unstable link status, resolve the problem, and check whether the trap persists.
6. Collect alarm information and configuration information, and then contact technical support personnel.
7. End.