ISIS_1.3.6.1.4.1.2011.5.25.24.2.4.1 hwIsisSystemIdConflict

Trap Buffer Description

System ID may conflict.(hwisisSysInstance=[hwisisSysInstance], hwisisSysLevelIndex=[hwisisSysLevelIndex], OwnSystemId=[OwnSystemId], sysProcIndexofDyname=[sysProcIndexofDyname], OwnDynamicName=[OwnDynamicName], AdjSystemId=[AdjSystemId], AdjDynamicName=[AdjDynamicName], LocalIP=[hwIsisLocalIP], AdjIP=[hwIsisAdjIP], RemoteIP=[hwIsisRemoteIP])

IS-IS detected conflicting system IDs.

Trap Attributes

Trap Attribute Description

Alarm or Event

Event

Trap Severity

Informational

Mnemonic Code

ISIS_SYS_ID_CONFLICT

Trap OID

1.3.6.1.4.1.2011.5.25.24.2.4.1

MIB

HUAWEI-ISIS-CONF-MIB

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Name

This is an event trap and does not involve alarm name.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

-

Trap Buffer Parameters

Parameter Description

hwisisSysInstance

Number of the IS-IS process.

hwisisSysLevelIndex

Level of the IS-IS process.

OwnSystemId

System ID of the local IS-IS process.

sysProcIndexofDyname

Index of the IS-IS process.

OwnDynamicName

Dynamic name of the local IS-IS process.

AdjSystemId

System ID of the IS-IS neighbor.

AdjDynamicName

Dynamic name of the IS-IS neighbor.

hwIsisLocalIP

Local IP address.

hwIsisAdjIP

IP address of a neighbor.

hwIsisRemoteIP

IP address of the remote device with the conflicting system ID.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.24.2.2.2

hwisisSysInstance

-

1.3.6.1.4.1.2011.5.25.24.2.2.3

hwisisSysLevelIndex

-

1.3.6.1.4.1.2011.5.25.24.2.2.4

hwIsisOwnSysID

-

1.3.6.1.4.1.2011.5.25.24.2.1.1.1.30

hwIsisProcDynamicName

hwIsisProcIdIndex

1.3.6.1.4.1.2011.5.25.24.2.2.5

hwIsisAdjSysID

-

1.3.6.1.4.1.2011.5.25.24.2.2.6

hwIsisAdjSysName

-

1.3.6.1.4.1.2011.5.25.24.2.2.9

hwIsisLocalIP

-

1.3.6.1.4.1.2011.5.25.24.2.2.11

hwIsisAdjIP

-

1.3.6.1.4.1.2011.5.25.24.2.2.10

hwIsisRemoteIP

-

Impact on the System

Link state protocol data units (LSPs) are frequently updated, and route flapping occurs.

Possible Causes

Two IS-IS routers in the topology have the same system ID.

Procedure

  • Modify the conflicting system ID to ensure that the system IDs of devices in the topology are unique.
  • Run the undo isis system-id auto-recover disable command on the device where a system ID conflict occurs to enable the device to automatically change the local system ID when a system ID conflict occurs on the network.
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.