VPWS PW redundancy reported a protect degraded alarm. (InterfaceIndex=[InterfaceIndex], InterfaceName=[InterfaceName], PrimaryPwId=[PrimaryPwId], PrimaryPwType=[PrimaryPwType], PrimaryPeerAddress=[PrimaryPeerAddress])
The protection for VPWS PW redundancy degraded.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Critical |
Mnemonic Code |
hwVpwsPwRedundancyDegradedExpand |
Trap OID |
1.3.6.1.4.1.2011.5.25.119.4.1.9.3 |
MIB |
HUAWEI-PWE3-MIB |
Alarm ID |
0x0d4e2029 |
Alarm Name |
hwVpwsPwRedundancyDegradedExpand |
Alarm Type |
qualityOfServiceAlarm |
Raise or Clear |
Raise |
Match trap |
L2VPN_1.3.6.1.4.1.2011.5.25.119.4.1.9.4 hwVpwsPwRedundancyDegradedClearExpand |
Parameter | Description |
---|---|
InterfaceIndex |
Index of an AC interface. |
InterfaceName |
Name of an AC interface. |
PrimaryPwId |
Primary PW ID. |
PrimaryPwType |
Primary PW type. |
PrimaryPeerAddress |
Peer IP address of the primary PW. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.119.4.1.8.1.1.15 |
hwPWVcIfIndexExpand |
hwPWVcIDExpand hwPWVcTypeExpand hwPWVcPeerAddrExpand |
1.3.6.1.4.1.2011.5.25.119.4.1.8.1.1.49 |
hwPWVcIfNameExpand |
hwPWVcIDExpand hwPWVcTypeExpand hwPWVcPeerAddrExpand |
1. Perform the troubleshooting operations described in hwPWVcDown to rectify the fault and then check whether the trap is cleared.
2. Collect alarm information and configuration information, and then contact technical support personnel.
3. End.