L2VPN_1.3.6.1.4.1.2011.5.25.119.9.2.37 hwL2vpnOamSd2Far

Trap Buffer Description

The OAM module reported an alarm, indicating that the far-end packet loss ratio exceeded the sd2 threshold. (ServiceType=[ServiceType], ProtocolType=[ProtocolType], VcID=[VcID], VcType=[VcType], PeerAddr=[PeerAddr], IfIndex=[IfIndex], PwMaster=[PwMaster], RmtSiteID=[RmtSiteID], InLabel=[InLabel], OutLabel=[OutLabel], IfName=[IfName], VsiName=[VsiName])

The far-end packet loss ratio exceeded the SD2 threshold.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Error

Mnemonic Code

hwL2vpnOamSd2Far

Trap OID

1.3.6.1.4.1.2011.5.25.119.9.2.37

MIB

HUAWEI-L2VPN-OAM-MIB

Alarm ID

0x00010080

Alarm Name

hwL2vpnOamSd2Far

Alarm Type

communicationsAlarm

Raise or Clear

Raise

Match trap

L2VPN_1.3.6.1.4.1.2011.5.25.119.9.2.38 hwL2vpnOamSd2FarClear

Trap Buffer Parameters

Parameter Description

ServiceType

Type of the service:

  • 0: VLL.
  • 1: VPLS.

ProtocolType

Type of the protocol:

  • 0: SVC.
  • 1: LDP.
  • 2: BGP (not supported for the time being).

VcID

VC ID.

VcType

VC type.

PeerAddr

IP address of the peer.

IfIndex

Interface index.

PwMaster

PW identifier:

  • 1: primary PW.
  • 2: secondary PW.

RmtSiteID

Remote site ID.

InLabel

VC in-label.

OutLabel

VC out-label.

IfName

Interface name.

VsiName

VSI name.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.119.9.1.1

hwL2vpnServiceType

-

1.3.6.1.4.1.2011.5.25.119.9.1.2

hwL2vpnProtocolType

-

1.3.6.1.4.1.2011.5.25.119.9.1.3

hwL2vpnVcID

-

1.3.6.1.4.1.2011.5.25.119.9.1.4

hwL2vpnVcType

-

1.3.6.1.4.1.2011.5.25.119.9.1.5

hwL2vpnPeerAddr

-

1.3.6.1.4.1.2011.5.25.119.9.1.6

hwL2vpnIfIndex

-

1.3.6.1.4.1.2011.5.25.119.9.1.7

hwL2vpnPwMaster

-

1.3.6.1.4.1.2011.5.25.119.9.1.8

hwL2vpnRmtSiteID

-

1.3.6.1.4.1.2011.5.25.119.9.1.9

hwL2vpnInLabel

-

1.3.6.1.4.1.2011.5.25.119.9.1.10

hwL2vpnOutLabel

-

1.3.6.1.4.1.2011.5.25.119.9.1.11

hwL2vpnIfName

-

1.3.6.1.4.1.2011.5.25.119.9.1.12

hwL2vpnVsiName

-

Impact on the System

Services will not be affected so long as the alarm reported by OAM indicates that there is no fault on the PW.

Possible Causes

The far-end packet loss ratio exceeded the SD2 (PTN and OSN are both SF) threshold.

Procedure

1. Perform the troubleshooting operations described in hwMplsTpOamFarDualLossSD2 to rectify the fault. Then, check whether the alarm is cleared.

  • If the alarm is cleared, go to Step 3.
  • If alarm persists, go to Step 2.

2. Collect alarm information and configuration information, and then contact technical support personnel.

3. End.