The peer link of the LACP member interface might be incorrectly connected. (TrunkIndex=[TrunkIndex], PortIfIndex=[PortIfIndex], TrunkId=[TrunkId], TrunkName=[TrunkName], PortName=[PortName])
The peer link of an Eth-Trunk member interface in LACP mode might be incorrectly connected.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Critical |
Mnemonic Code |
hwLacpPartnerMisconnect |
Trap OID |
1.3.6.1.4.1.2011.5.25.41.3.51 |
MIB |
HUAWEI-IF-EXT-MIB |
Alarm ID |
0x09362011 |
Alarm Name |
hwLacpPartnerMisconnect |
Alarm Type |
communicationsAlarm |
Raise or Clear |
Raise |
Match trap |
LACP_1.3.6.1.4.1.2011.5.25.41.3.52 hwLacpPartnerMisconnectResume |
Parameter | Description |
---|---|
TrunkIndex |
Trunk index |
PortIfIndex |
Index of a trunk member interface |
TrunkId |
ID of a trunk interface |
TrunkName |
Name of a trunk interface |
PortName |
Name of a trunk member interface |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.41.1.3.3.1.2 |
hwTrunkIfID |
hwTrunkIndex |
1.3.6.1.2.1.31.1.1.1.1 |
ifName |
ifIndex |
1.3.6.1.2.1.31.1.1.1.1 |
ifName |
ifIndex |
1. Check whether the peer link is incorrectly connected and added to an incorrect link aggregation group. If the peer link is incorrectly connected, go to Step 2.
2. Correctly configure the link aggregation group at the peer end, and then check whether the trap message is cleared. If the trap message persists, go to Step 3.
3. Collect alarm information and configuration information, and then contact technical support personnel.