LACP_1.3.6.1.4.1.2011.5.25.41.3.58 hwLacpStateDown

Trap Buffer Description

The LACP status of the member port changes to down. (TrunkIndex=[TrunkIndex],PortIfIndex=[PortIfIndex],TrunkId=[TrunkId],TrunkName=[TrunkName],PortName=[PortName],Reason=[ReasonCode])

The LACP status of the member interface is Down.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Critical

Mnemonic Code

hwLacpStateDown

Trap OID

1.3.6.1.4.1.2011.5.25.41.3.58

MIB

HUAWEI-IF-EXT-MIB

Alarm ID

0x09362015

Alarm Name

hwLacpStateDown

Alarm Type

communicationsAlarm

Raise or Clear

Raise

Match trap

LACP_1.3.6.1.4.1.2011.5.25.41.3.59 hwLacpStateDownResume

Trap Buffer Parameters

Parameter Description

TrunkIndex

Trunk index

PortIfIndex

Index of a member port

TrunkId

Trunk interface ID

TrunkName

Trunk interface name

PortName

Member port name

ReasonCode

Cause of the alarm

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.41.1.3.3.1.2

hwTrunkIfID

hwTrunkIndex

1.3.6.1.2.1.31.1.1.1.1

ifName

ifIndex

1.3.6.1.2.1.31.1.1.1.1

ifName

ifIndex

Impact on the System

The link cannot carry services.

Possible Causes

LACP negotiation fails.

Procedure

1. Run the display this command in the interface view to check whether the interfaces at both ends are shut down.

  • If the interfaces are shut down, run the undo shutdown command to enable the interfaces. Then, check whether the alarm is cleared. If the alarm persists, go to Step 2.
  • If the interfaces are not shut down, go to Step 2.

2. Check whether the physical connection is normal. For example, check whether the network cable or optical module is loose or disconnected.

  • If the physical link is abnormal, reconnect the physical link and check whether the alarm is cleared. If the alarm persists, go to Step 3.
  • If the physical link is normal, go to Step 3.

3. Run the display interface eth-trunk command in the system view to check whether an interface on the local or peer device is removed from the Eth-Trunk.

  • If the interface is removed from the Eth-Trunk abnormally, run the eth-trunk command in the member interface view or run the trunkport command in the Eth-Trunk interface view to add the interface to the Eth-Trunk again. Then, check whether the alarm is cleared. If the alarm persists, go to Step 4.
  • If the interface is removed from the Eth-Trunk, go to Step 4.

4. Collect alarm, log, and configuration information, and contact technical support personnel.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >