LDT_1.3.6.1.4.1.2011.25.180.2.9 hwAutoLoopDetectTriggerDown

Trap Buffer Description

The interface turned to trigger-down state,because of the loop detected on this interface. (Interface=[IfName], VlanId=[VlanId], InstName=[vsi_name])

The interface turned to the trigger-down state because a loop was detected on this interface.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwAutoLoopDetectTriggerDown

Trap OID

1.3.6.1.4.1.2011.25.180.2.9

MIB

HUAWEI-LOOPDETECT-MIB

Alarm ID

0x09a12006

Alarm Name

hwAutoLoopDetectAlarm

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

LDT_1.3.6.1.4.1.2011.25.180.2.10 hwAutoLoopDetectUnTriggerDown

Trap Buffer Parameters

Parameter Description

IfName

Interface name.

VlanId

VLAN ID.

vsi_name

VSI name.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.25.180.13.1.1

hwAutoLoopDetectTrapPortName

hwAutoLoopDetectTrapPortName

1.3.6.1.4.1.2011.25.180.13.1.2

hwAutoLoopDetectTrapVlan

hwAutoLoopDetectTrapPortName

1.3.6.1.4.1.2011.25.180.13.1.3

hwAutoLoopDetectTrapVsiName

hwAutoLoopDetectTrapPortName

Impact on the System

  • Cause 1: A loop was detected on the interface that has proactive loop detection enabled after it went Up. The interface was then blocked.

    The interface was blocked.

  • Cause 2: A loop was detected on the interface that has proactive loop detection enabled after it went Up.

    A loop is detected.

Possible Causes

  • Cause 1: A loop was detected on the interface that has proactive loop detection enabled after it went Up. The interface was then blocked.
  • Cause 2: A loop was detected on the interface that has proactive loop detection enabled after it went Up.

Procedure

  • Cause 1: A loop was detected on the interface that has proactive loop detection enabled after it went Up. The interface was then blocked.

    1.Run the display loop-detect trigger trigger-down all command to check whether there is an interface in the trigger-down state.

    • If so, go to Step 2.
    • If not, go to Step 4.

    2.Check whether the interface connection has a loop.

    • If so, go to Step 3.
    • If not, go to Step 4.

    3.After removing the interface loop, run the reset loop-detect trigger trigger-down command to unblock the interface, and check whether the alarm is released.

    • If so, go to Step 5.
    • If not, go to Step 4.

    4.Collect alarm information, log information and configuration information, and then contact technical support personnel.

    5.End.

  • Cause 2: A loop was detected on the interface that has proactive loop detection enabled after it went Up.

    1.Run the display loop-detect trigger trigger-down all command to check whether there is an interface in the trigger-down state.

    • If so, go to Step 2.
    • If not, go to Step 3.

    2.Check whether loops occur on the interface and the Layer 2 network connected to the interface.

    • If so, go to Step 4.
    • If not, go to Step 3.

    3.Collect trap, log, and configuration information, and contact technical support personnel.

    4.End.