MFLP_1.3.6.1.4.1.2011.5.25.160.3.21 hwMflpBdAcBlock

Trap Buffer Description

The AC interface turned to block state. (BD=[bdid], ACInterfaceName=[acifname], BlockTime=[blocktime], BlockReason=[blockreason], DetectMAC=[mac])

An AC-side interface is blocked.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwMflpBdAcBlock

Trap OID

1.3.6.1.4.1.2011.5.25.160.3.21

MIB

HUAWEI-MFLP-MIB

Alarm ID

0x00F10117

Alarm Name

hwMflpBdAcBlock

Alarm Type

communicationsAlarm

Raise or Clear

Raise

Match trap

MFLP_1.3.6.1.4.1.2011.5.25.160.3.22 hwMflpBdAcResume

Trap Buffer Parameters

Parameter Description

bdid

Bridge domain ID

acifname

AC-side interface name

blocktime

Blocking time

blockreason

Reason for the blocking

mac

Detected MAC address

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.160.1.3.1.1

hwMflpBdIndex

hwMflpBdIndex

1.3.6.1.4.1.2011.5.25.160.1.3.1.3

hwMflpBdCfgAcName

hwMflpBdIndex

1.3.6.1.4.1.2011.5.25.160.1.3.1.2

hwMflpBdCfgBlockTime

hwMflpBdIndex

1.3.6.1.4.1.2011.5.25.160.1.3.1.4

hwMflpBdCfgAlarmReason

hwMflpBdIndex

1.3.6.1.4.1.2011.5.25.160.1.3.1.5

hwMflpBdDetectMAC

hwMflpBdIndex

Impact on the System

Traffic on the AC-side interface in the BD cannot be forwarded.

Possible Causes

  • Cause 1: The AC has been blocked for BD loop, and the AC has already been permanently blocked.
  • Cause 2: The AC has been blocked for BD loop, and the loop has already been punished times times.

Procedure

  • Cause 1: The AC has been blocked for BD loop, and the AC has already been permanently blocked.

    1. Run the display current-configuration command to check whether the loopback local command is configured on AC-side interfaces corresponding to the BD.

    • If the loopback local command is configured on AC-side interfaces corresponding to the BD, delete the command configuration and check whether the alarm is cleared. If the alarm persists, go to Step 2.
    • If the loopback local command is not configured on AC-side interfaces corresponding to the BD, go to Step 2.

    2. Log in to the device and run the reset loop-detect eth-loop bridge-domain bd-id { all | interface interfacetype interfacenumber } command to unblock the PW and check whether hwMflpAcResume is reported. If hwMflpAcResume is not reported, go to Step 3.

    3. Collect alarm information and configuration information, and then contact technical support personnel.

  • Cause 2: The AC has been blocked for BD loop, and the loop has already been punished times times.

    1. Run the display current-configuration command to check whether the loopback local command is configured on AC-side interfaces corresponding to the BD.

    • If the loopback local command is configured on AC-side interfaces corresponding to the BD, delete the command configuration and check whether the alarm is cleared. If the alarm persists, go to Step 2.
    • If the loopback local command is not configured on AC-side interfaces corresponding to the BD, go to Step 2.

    2. Check whether the AC-side interface recovers after the block-time specified in the loop-detect eth-loop command expires. If the AC-side interface does not recover, go to Step 3.

    3. Collect alarm information and configuration information, and then contact technical support personnel.