Alarm only when loop existed in BD. (BD=[bdid], AlarmReason=[alarmreason], DetectMAC=[detectMAC], InterfaceName1=[AcName1], InterfaceName2=[AcName2], InterfaceName3=[AcName3])
Only an alarm is sent when a loop occurs in a BD.
Trap Attribute | Description |
---|---|
Alarm or Event |
Event |
Trap Severity |
Warning |
Mnemonic Code |
MFLP_BD_ALARM |
Trap OID |
1.3.6.1.4.1.2011.5.25.160.3.25 |
MIB |
HUAWEI-MFLP-MIB |
Alarm ID |
This is an event trap and does not involve alarm ID. |
Alarm Name |
This is an event trap and does not involve alarm name. |
Alarm Type |
This is an event trap and does not involve alarm type. |
Raise or Clear |
This is an event trap and does not involve alarm generation or clearance. |
Match trap |
- |
Parameter | Description |
---|---|
bdid |
Bridge domain ID. |
alarmreason |
Causes for the alarm. |
detectMAC |
MAC address that flaps. |
AcName1 |
Name of interface 1 on which MAC address flaps. |
AcName2 |
Name of interface 2 on which MAC address flaps. |
AcName3 |
Name of interface 3 on which MAC address flaps. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.160.1.3.1.1 |
hwMflpBdIndex |
hwMflpBdIndex |
1.3.6.1.4.1.2011.5.25.160.1.3.1.3 |
hwMflpBdCfgAcName |
hwMflpBdIndex |
1.3.6.1.4.1.2011.5.25.160.1.3.1.6 |
hwMflpBdCfgAcNameEx1 |
hwMflpBdIndex |
1.3.6.1.4.1.2011.5.25.160.1.3.1.7 |
hwMflpBdCfgAcNameEx2 |
hwMflpBdIndex |
1.3.6.1.4.1.2011.5.25.160.1.3.1.4 |
hwMflpBdCfgAlarmReason |
hwMflpBdIndex |
1.3.6.1.4.1.2011.5.25.160.1.3.1.5 |
hwMflpBdDetectMAC |
hwMflpBdIndex |
1. Run the display current-configuration command to check whether the loopback local command is configured on AC-side interfaces corresponding to the BD.
2. Run the display loop-detect eth-loop command to check whether Action is displayed as Alarm-only.
3. For the BD in the alarm, perform either of the following steps:
4. Collect log information and configuration information, and then contact technical support personnel.
1. Run the display current-configuration command to check whether the loopback local command is configured on AC-side interfaces corresponding to the BD.