MFLP_1.3.6.1.4.1.2011.5.25.160.3.3 hwMflpAcBlock

Trap Buffer Description

The AC interface turned to block state. (Vsi Name=[vsiname], AC Interface Name=[acifname], Block Time=[blocktime], Block Reason=[blockreason], DetectMAC=[mac])

An AC-side interface is blocked.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwMflpAcBlock

Trap OID

1.3.6.1.4.1.2011.5.25.160.3.3

MIB

HUAWEI-MFLP-MIB

Alarm ID

0x0d582006

Alarm Name

hwMflpAcBlock

Alarm Type

communicationsAlarm

Raise or Clear

Raise

Match trap

MFLP_1.3.6.1.4.1.2011.5.25.160.3.4 hwMflpAcResume

Trap Buffer Parameters

Parameter Description

vsiname

VSI name

acifname

AC-side interface name

blocktime

Blocking time

blockreason

Reason for the blocking

mac

Detected MAC address

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.160.1.2.1.9

hwMflpVsiCfgAcName

hwMflpVsiName

1.3.6.1.4.1.2011.5.25.160.1.2.1.6

hwMflpVsiCfgBlockTime

hwMflpVsiName

1.3.6.1.4.1.2011.5.25.160.1.2.1.10

hwMflpVsiCfgAlarmReason

hwMflpVsiName

1.3.6.1.4.1.2011.5.25.160.1.2.1.14

hwMflpVsiDetectMAC

hwMflpVsiName

Impact on the System

Traffic on the AC-side interface in the VSI cannot be forwarded.

Possible Causes

  • Cause 1: The AC has been blocked for VSI loop, and the AC has already been permanently blocked.
  • Cause 2: The AC has been blocked for VSI loop, and the loop has already been punished times times.

Procedure

  • Cause 1: The AC has been blocked for VSI loop, and the AC has already been permanently blocked.

    1. Run the display current-configuration command to check whether the loopback local command is configured on AC-side interfaces corresponding to the VSI.

    • If the loopback local command is configured on AC-side interfaces corresponding to the VSI, delete the command configuration and check whether the alarm is cleared. If the alarm persists, go to Step 2.
    • If the loopback local command is not configured on AC-side interfaces corresponding to the VSI, go to Step 2.

    2. Log in to the device and run the reset loop-detect eth-loop vsi vsi-name { all | interface interfacetype interfacenumber } command to unblock the PW and check whether hwMflpAcResume is reported. If hwMflpAcResume is not reported, go to Step 3.

    3. Collect alarm information and configuration information, and then contact technical support personnel.

  • Cause 2: The AC has been blocked for VSI loop, and the loop has already been punished times times.

    1. Run the display current-configuration command to check whether the loopback local command is configured on AC-side interfaces corresponding to the VSI.

    • If the loopback local command is configured on AC-side interfaces corresponding to the VSI, delete the command configuration and check whether the alarm is cleared. If the alarm persists, go to Step 2.
    • If the loopback local command is not configured on AC-side interfaces corresponding to the VSI, go to Step 2.

    2. Check whether the AC-side interface recovers after the block-time specified in the loop-detect eth-loop command expires. If the AC-side interface does not recover, go to Step 3.

    3. Collect alarm information and configuration information, and then contact technical support personnel.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >