The tunnel receives a MEP alarm. (SessionTunnelId=[SessionTunnelId], LocalLspId=[LocalLspId], IngressLsrId=[IngressLsrId], EgressLsrId=[EgressLsrId], TunnelName=[TunnelName], SignalingProtocol=[SgnlPrtcl])
MEP IDs on two ends of an MPLS tunnel were different.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Critical |
Mnemonic Code |
hwMplsOamMep |
Trap OID |
1.3.6.1.4.1.2011.5.25.121.2.1.26 |
MIB |
HUAWEI-MPLS-EXTEND-MIB |
Alarm ID |
0x0001005e |
Alarm Name |
hwMplsOamMep |
Alarm Type |
communicationsAlarm |
Raise or Clear |
Raise |
Match trap |
MPLS_LSPM_1.3.6.1.4.1.2011.5.25.121.2.1.27 hwMplsOamMepRecovery |
Parameter | Description |
---|---|
SessionTunnelId |
Tunnel ID |
LocalLspId |
Local LSP ID |
IngressLsrId |
ID of the ingress LSR |
EgressLsrId |
ID of the egress LSR |
TunnelName |
Tunnel name |
SgnlPrtcl |
Tunneling protocol |
LsrRole |
Lsp Lsr Role. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.121.1.1.1.29 |
hwMplsTunnelInterfaceName |
hwMplsTunnelIndex hwMplsTunnelInstance hwMplsTunnelIngressLSRId hwMplsTunnelEgressLSRId |
1.3.6.1.4.1.2011.5.25.121.1.1.1.30 |
hwMplsTunnelSignalProto |
hwMplsTunnelIndex hwMplsTunnelInstance hwMplsTunnelIngressLSRId hwMplsTunnelEgressLSRId |
1. Run the display current-configuration command to check whether IDs of the ingress and egress MEPs are the same.
2. Set a same ID for the ingress and egress MEPs.
3. Collect the trap information, log information, and configuration information, and then Collect alarm information and configuration information, and then contact technical support personnel..
4. End.