MPLS_LSPM_1.3.6.1.4.1.2011.5.25.121.2.1.3 hwMplsStaticCRLspUp

Trap Buffer Description

Static CR-LSP went Up. (LspIndex=[LspIndex], InSegmentIndex=[InSegmentIndex], OutSegmentIndex=[OutSegmentIndex], OutIfIndex=[OutIfIndex], LspName=[LspName], LspStatus=[LspStatus], OutIfName=[OutIfName], InIfIndex=[InIfIndex], InIfName=[InIfName], DownReason=[DownReason])

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Critical

Mnemonic Code

hwMplsStaticCRLspDown

Trap OID

1.3.6.1.4.1.2011.5.25.121.2.1.3

MIB

HUAWEI-MPLS-EXTEND-MIB

Alarm ID

0x00F10071

Alarm Name

hwMplsStaticCRLspDown

Alarm Type

communicationsAlarm

Raise or Clear

Clear

Match trap

MPLS_LSPM_1.3.6.1.4.1.2011.5.25.121.2.1.4 hwMplsStaticCRLspDown

Trap Buffer Parameters

Parameter Description

LspIndex

Indicates the index of the LSP.

InSegmentIndex

Indicates the inSegment index of a static CR-LSP.

OutSegmentIndex

Indicates the outSegment index of a static CR-LSP.

OutIfIndex

Indicates the outbound interface index of a static CR-LSP.

LspName

Indicates the name of a static CR-LSP.

LspStatus

Indicates the status of a static CR-LSP.

OutIfName

Indicates the outbound interface name of a static CR-LSP.

InIfIndex

Indicates the inbound interface index of a static CR-LSP.

InIfName

Indicates the inbound interface name a static CR-LSP.

DownReason

Indicates the reason that the static CR-LSP down.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.121.1.5.1.5

hwStaticLspName

hwStaticLspIndex

hwStaticLspInSegmentIndex

hwStaticLspOutSegmentIndex

1.3.6.1.4.1.2011.5.25.121.1.5.1.6

hwStaticLspStatus

hwStaticLspIndex

hwStaticLspInSegmentIndex

hwStaticLspOutSegmentIndex

1.3.6.1.2.1.31.1.1.1.1

ifName

ifIndex

1.3.6.1.4.1.2011.5.25.121.1.11

hwStaticLspInIfIndex

-

1.3.6.1.4.1.2011.5.25.121.1.12

hwStaticLspInIfName

-

1.3.6.1.4.1.2011.5.25.121.1.13

hwStaticLspDownReason

-

Impact on the System

Services are not affected.

Possible Causes

  • Cause 2: static CR-LSP up
  • Cause 7: Static CR-LSP configuration delete

Procedure

This trap message is informational only, and no action is required.