MPLS_LSPM_1.3.6.1.4.1.2011.5.25.121.2.1.40 hwMplsOamUnknown

Trap Buffer Description

The tunnel receives an Unknown alarm. (SessionTunnelId=[SessionTunnelId], LocalLspId=[LocalLspId], IngressLsrId=[IngressLsrId], EgressLsrId=[EgressLsrId], TunnelName=[TunnelName], SignalingProtocol=[SgnlPrtcl], SignalledTunnelName=[SignalledTunnelName])

An unknown error occurred on an MPLS tunnel.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Critical

Mnemonic Code

MPLS_TUNNEL_UNKNOWN

Trap OID

1.3.6.1.4.1.2011.5.25.121.2.1.40

MIB

HUAWEI-MPLS-EXTEND-MIB

Alarm ID

0x00010060

Alarm Name

hwMplsOamUnknown

Alarm Type

communicationsAlarm

Raise or Clear

Raise

Match trap

MPLS_LSPM_1.3.6.1.4.1.2011.5.25.121.2.1.41 hwMplsOamUnknownRecovery

Trap Buffer Parameters

Parameter Description

SessionTunnelId

Tunnel Id

LocalLspId

Local Lsp Id

IngressLsrId

Ingress Lsr Id

EgressLsrId

Egress Lsr Id

TunnelName

Tunnel Interface Name

SgnlPrtcl

Tunnel Signal Protocol: - 1: RSVP - 2: STATIC - 3: CRSTATIC PTN7900,PTN9X0: - 1: RSVP - 2: STATIC - 3: CRSTATIC - 4: SEGMENT_ROUTING

SignalledTunnelName

User-Defined Tunnel Name

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.121.1.1.1.29

hwMplsTunnelInterfaceName

hwMplsTunnelIndex

hwMplsTunnelInstance

hwMplsTunnelIngressLSRId

hwMplsTunnelEgressLSRId

1.3.6.1.4.1.2011.5.25.121.1.1.1.30

hwMplsTunnelSignalProto

hwMplsTunnelIndex

hwMplsTunnelInstance

hwMplsTunnelIngressLSRId

hwMplsTunnelEgressLSRId

1.3.6.1.4.1.2011.5.25.121.1.1.1.33

hwMplsTunnelSignalledTunnelName

hwMplsTunnelIndex

hwMplsTunnelInstance

hwMplsTunnelIngressLSRId

hwMplsTunnelEgressLSRId

Impact on the System

This alarm triggers a primary/backup LSP switchover.

Possible Causes

Tunnel OAM configurations were different on the source and sink NEs of a tunnel. The possible cause was that the detection packet type or detection period may be set incorrectly.

Procedure

1.Run the display mpls oam ingress and display mpls oam egress commands to check whether OAM detection configurations on both ends are the same. - If so, go to Step 3. - If not, go to Step 2. 2.Reconfigure the OAM function on both ends. Then check whether MPLS_LSPM_1.3.6.1.4.1.2011.5.25.121.2.1.41 hwMplsOamUnknownRecovery is reported.. - If so, go to Step 4. - If not, go to Step 3. 3.Collect the alarm, log, and configuration information, and contact technical support personnel. 4.End.