MPLS_LSPM_1.3.6.1.4.1.2011.5.25.121.2.1.42 hwMplsOamBDI

Trap Buffer Description

The tunnel receives a BDI alarm. (SessionTunnelId=[SessionTunnelId], LocalLspId=[LocalLspId], IngressLsrId=[IngressLsrId], EgressLsrId=[EgressLsrId], IfIndex=[OutIfIndex], TunnelName=[TunnelName], SignalingProtocol=[SgnlPrtcl], IfName=[OutIfName], SignalledTunnelName=[SignalledTunnelName])

A BDI alarm about an MPLS tunnel was generated.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Error

Mnemonic Code

MPLS_TUNNEL_BDI

Trap OID

1.3.6.1.4.1.2011.5.25.121.2.1.42

MIB

HUAWEI-MPLS-EXTEND-MIB

Alarm ID

0x00010051

Alarm Name

hwMplsOamBDI

Alarm Type

communicationsAlarm

Raise or Clear

Raise

Match trap

MPLS_LSPM_1.3.6.1.4.1.2011.5.25.121.2.1.43 hwMplsOamBDIRecovery

Trap Buffer Parameters

Parameter Description

SessionTunnelId

Tunnel ID

LocalLspId

Local LSP ID

IngressLsrId

ID of the ingress LSR

EgressLsrId

ID of the egress LSR

OutIfIndex

Index of the interface

TunnelName

Tunnel name

SgnlPrtcl

Tunneling protocol

OutIfName

The name of the interface

SignalledTunnelName

Tunnel alias.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.121.1.1.1.29

hwMplsTunnelInterfaceName

hwMplsTunnelIndex

hwMplsTunnelInstance

hwMplsTunnelIngressLSRId

hwMplsTunnelEgressLSRId

1.3.6.1.4.1.2011.5.25.121.1.1.1.30

hwMplsTunnelSignalProto

hwMplsTunnelIndex

hwMplsTunnelInstance

hwMplsTunnelIngressLSRId

hwMplsTunnelEgressLSRId

1.3.6.1.2.1.31.1.1.1.1

ifName

ifIndex

1.3.6.1.4.1.2011.5.25.121.1.1.1.33

hwMplsTunnelSignalledTunnelName

hwMplsTunnelIndex

hwMplsTunnelInstance

hwMplsTunnelIngressLSRId

hwMplsTunnelEgressLSRId

Impact on the System

If a protection group is configured correctly, the alarm triggers a primary/backup LSP switchover.

Possible Causes

An MPLS tunnel is faulty. The egress sends a BDI notification to the ingress.

Procedure

1. Run the display interface command to check whether any physical interface connected to the MPLS tunnel is shut down.

  • If so, go to Step 2.
  • If not, go to Step 3.

2. Run the undo shutdown command to enable the physical interface. Then check whether the alarm is cleared.

  • If so, go to Step 5.
  • If not, go to Step 4.

3. If all configurations are correct, the MPLS tunnel is faulty. Then go to Step 4.

4. Collect the trap information, log information, and configuration information, and then Collect alarm information and configuration information, and then contact technical support personnel..

5. End.