MPLS_LSPM_1.3.6.1.4.1.2011.5.25.121.2.1.98 hwMplsSlotResTotalCountExceed

Trap Buffer Description

The number of used MPLS resources on the interface board reached the maximum number. (hwMplsResourceType=[ResourceType], hwMplsChassis=[Chassis], hwMplsSlot=[Slot], hwMplsResourceTotalCount=[ResourceTotalCount])

The number of MPLS resources on the interface board reached the maximum value.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Critical

Mnemonic Code

hwMplsSlotResTotalCountExceed

Trap OID

1.3.6.1.4.1.2011.5.25.121.2.1.98

MIB

HUAWEI-MPLS-EXTEND-MIB

Alarm ID

0x00f10434

Alarm Name

hwMplsSlotResTotalCountExceed

Alarm Type

qualityOfServiceAlarm

Raise or Clear

Raise

Match trap

MPLS_LSPM_1.3.6.1.4.1.2011.5.25.121.2.1.99 hwMplsSlotResTotalCountExceedClear

Trap Buffer Parameters

Parameter Description

ResourceType

Resource type

Chassis

Number of the chassis where the interface board is located

Slot

Slot number of the interface board

ResourceTotalCount

Maximum number of resources supported by an interface board

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.121.2.2.11

hwMplsResourceType

-

1.3.6.1.4.1.2011.5.25.121.2.2.24

hwMplsChassis

-

1.3.6.1.4.1.2011.5.25.121.2.2.23

hwMplsSlot

-

1.3.6.1.4.1.2011.5.25.121.2.2.14

hwMplsResourceTotalCount

-

Impact on the System

The number of MPLS resources of the corresponding type on the current interface board has reached the total capacity, and no new MPLS resources of this type are available, which may affect the establishment of normal services.

Possible Causes

The number of used MPLS resources on the interface board reached the maximum number.

Procedure

1. Based on the MPLS resource type, check whether the resource usage exceeds the threshold.

2. Reduce the configurations or messages that trigger the creation of related resources to reduce the usage of MPLS resources of the corresponding type. Then, check whether the alarm is cleared.

  • If the alarm is cleared, go to Step 4.
  • If the alarm persists, go to Step 3.

3. Collect alarm and configuration information, and contact technical support personnel.

4. End

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >