MRM_1.3.6.1.4.1.2011.5.25.149.1.2.17 hwMcastEntryExceed

Trap Buffer Description

Multicast routing total entries of all instances cannot be created because the limit is reached. (LimitType=[LimitType], AddressFamily=[AddressFamily], LimitCount=[LimitCount])

Multicast routing entry cannot be created because the multicast routing entry limit is reached.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Critical

Mnemonic Code

hwVsMcastEntryExceed

Trap OID

1.3.6.1.4.1.2011.5.25.149.1.2.17

MIB

HUAWEI-IPMCAST-MIB

Alarm ID

0x0a592001

Alarm Name

hwMcastEntryExceed

Alarm Type

qualityOfServiceAlarm

Raise or Clear

Raise

Match trap

MRM_1.3.6.1.4.1.2011.5.25.149.1.2.18 hwMcastEntryExceedClear

Trap Buffer Parameters

Parameter Description

LimitType

Limit type

AddressFamily

Address family

LimitCount

Limit value

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.149.1.1.1.33

hwMcastEntryLimitType

-

1.3.6.1.4.1.2011.5.25.149.1.1.1.34

hwMcastNotificationAddressType

-

1.3.6.1.4.1.2011.5.25.149.1.1.1.35

hwMcastEntryTotalCount

-

Impact on the System

Multicast routing entry cannot be created because the number of multicast routing entries reaches the upper limit.

Possible Causes

  • Cause 1: A New entry was added, so that the number of multicast routing entries in all instances reached the limit.
  • Cause 2: The limit on the number of multicast routing entries in all instance was changed to a smaller value, so that the number of multicast routing entries in all instances reached the limit.

Procedure

The procedures of cause 1 and cause 2 are the same.

1. Run the display virtual-system resource command to check whether the m4route resource limit value is low.

  • If the limit is low, go to Step 2.
  • If the limit is not low, go to Step 3.

2. Run the resource m4route upper-limit resource-limit command on the VS that the alarm is generated, change the resource limit value to a lager value. Check whether the alarm is cleared.

  • If the alarm is cleared, go to Step 4.
  • If the alarm persists, go to Step 3.

3. Collect alarm information and configuration information, and then contact technical support personnel.

4. End.