NAT_1.3.6.1.4.1.2011.5.25.240.2.114 hwCGNUserPortUseUpAlarm

Trap Buffer Description

The number of ports is used up. (Protocol=[Protocol], CPEIP=[CPEIP], InstanceType=[InstanceType], InstanceName=[InstanceName], AddrGroupName=[AddrGroupName], Threshold=[Threshold], Ports=[Ports], Slot=[Slot], Cpu=[Cpu], UserID=[UserID])

User-based ports are used up.

In VS mode, this trap is supported only by the admin VS.

This alarm is supported only on NetEngine 8000 F1A.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwCGNUserPortUseUpAlarm

Trap OID

1.3.6.1.4.1.2011.5.25.240.2.114

MIB

HUAWEI-DSLITE-MIB

Alarm ID

0x00f103a9

Alarm Name

hwCGNUserPortUseUpAlarm

Alarm Type

communicationsAlarm

Raise or Clear

Raise

Match trap

NAT_1.3.6.1.4.1.2011.5.25.240.2.115 hwCGNUserPortUseUpResumeAlarm

Trap Buffer Parameters

Parameter Description

Protocol

Protocol type. The value is TOTAL.

CPEIP

CPE IP address.

InstanceType

Instance type.

InstanceName

Instance name.

AddrGroupName

Name of an IP address pool.

Threshold

Threshold of the proportion of CGN interfaces assigned to users to the total supported ones.

Ports

Number of used ports.

Slot

Slot ID of a service board.

Cpu

CPU ID of the service board.

UserID

User ID.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.240.1.2.4

hwCGNAlarmProtocolType

-

1.3.6.1.4.1.2011.5.25.240.1.2.3

hwCGNAlarmCpeIpAddr

-

1.3.6.1.4.1.2011.5.25.240.1.2.2

hwCGNAlarmInstanceType

-

1.3.6.1.4.1.2011.5.25.240.1.2.7

hwCGNAlarmInstanceName

-

1.3.6.1.4.1.2011.5.25.240.1.2.5

hwCGNAlarmAddrGroupName

-

1.3.6.1.4.1.2011.5.25.240.1.2.8

hwVSUAlarmThreshold

-

1.3.6.1.4.1.2011.5.25.240.1.2.9

hwCGNAlarmPortNum

-

1.3.6.1.4.1.2011.5.25.240.1.2.10

hwVSUAlarmSlot

-

1.3.6.1.4.1.2011.5.25.240.1.2.11

hwVSUAlarmCpu

-

1.3.6.1.4.1.2011.5.25.240.1.2.13

hwCGNAlarmCid

-

Impact on the System

If new sessions are created, service flows fail to be created.

Possible Causes

The number of user ports is used up.

Procedure

Collect alarm, log, and configuration information, and contact technical support engineers.
Copyright © Huawei Technologies Co., Ltd.