NAT_1.3.6.1.4.1.2011.5.25.240.2.28 hwCGNNoPatAddrGroupExhaustAlarm

Trap Buffer Description

Addresses in the NO-PAT public address pool ran out. (AddrGroupName=[AddrGroupName], InstanceType=[InstanceType], InstanceName=[InstanceName], Pre-IPNum=[IPNum], Slot =[Slot], Cpu=[Cpu])

The IP addresses in a specified NO-PAT address pool were used up.

In VS mode, this trap is supported only by the admin VS.

This alarm is supported only on NetEngine 8000 F1A.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Critical

Mnemonic Code

hwCGNNoPatAddrGroupExhaustAlarm

Trap OID

1.3.6.1.4.1.2011.5.25.240.2.28

MIB

HUAWEI-DSLITE-MIB

Alarm ID

0x00F10019

Alarm Name

hwCGNNoPatAddrGroupExhaustAlarm

Alarm Type

communicationsAlarm

Raise or Clear

Raise

Match trap

NAT_1.3.6.1.4.1.2011.5.25.240.2.29 hwCGNNoPatAddrGroupExhaustResumeAlarm

Trap Buffer Parameters

Parameter Description

AddrGroupName

Name of an IP address pool.

InstanceType

Instance type.

InstanceName

Instance name.

IPNum

Number of used IP addresses.

Slot

Slot ID of a service board.

Cpu

CPU ID of the service board.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.240.1.2.5

hwCGNAlarmAddrGroupName

-

1.3.6.1.4.1.2011.5.25.240.1.2.2

hwCGNAlarmInstanceType

-

1.3.6.1.4.1.2011.5.25.240.1.2.7

hwCGNAlarmInstanceName

-

1.3.6.1.4.1.2011.5.25.240.1.2.16

hwCGNAlarmIPNum

-

1.3.6.1.4.1.2011.5.25.240.1.2.10

hwVSUAlarmSlot

-

1.3.6.1.4.1.2011.5.25.240.1.2.11

hwVSUAlarmCpu

-

Impact on the System

CGN is not available

Possible Causes

The IP addresses in a specified NO-PAT address pool were used up.

Procedure

1.Reduce used address number.

2.Collect trap, log, and configuration information, and then contact technical support personnel.