OSPF_1.3.6.1.4.1.2011.5.25.155.31.19 hwOspfv2GreaterAgeLsaRecived

Trap Buffer Description

OSPF receive LSA with greater Lsa-Age.(ProcessId=[ProcessId], AreaId=[AreaId], IfIndex=[IfIndex], NbrIPaddress=[NbrIpAddress], IfName=[IfName], NbrRtrId=[NbrRtrId], LsaId=[LsaId], LsaAge=[LsaAge])

This object indicates that the aging time of a received LSA is greater than 1800s.

Trap Attributes

Trap Attribute Description

Alarm or Event

Event

Trap Severity

Informational

Mnemonic Code

OSPFV2_GREATER_AGE_LSA_RECIVED

Trap OID

1.3.6.1.4.1.2011.5.25.155.31.19

MIB

HUAWEI-OSPFV2-MIB

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Name

This is an event trap and does not involve alarm name.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

-

Trap Buffer Parameters

Parameter Description

ProcessId

ID of an OSPF process.

AreaId

Area ID.

IfIndex

Interface index.

NbrIpAddress

IP address of a neighbor.

IfName

Interface name.

NbrRtrId

Router ID of a neighbor.

LsaId

LSA ID.

LsaAge

Aging time of the LSA.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.155.3.1.1

hwOspfv2ProcessIdIndex

hwOspfv2ProcessIdIndex

1.3.6.1.4.1.2011.5.25.155.6.1.9

hwOspfv2NbrRouterId

hwOspfv2ProcessIdIndex

hwOspfv2AreaIdIndex

hwOspfv2SelfIfnetIndex

hwOspfv2NbrIpAddrIndex

1.3.6.1.4.1.2011.5.25.155.6.1.5

hwOspfv2SelfIfName

hwOspfv2ProcessIdIndex

hwOspfv2AreaIdIndex

hwOspfv2SelfIfnetIndex

hwOspfv2NbrIpAddrIndex

1.3.6.1.4.1.2011.5.25.155.30.7

hwOspfv2LsaId

-

1.3.6.1.4.1.2011.5.25.155.30.8

hwOspfv2LsaAge

-

Impact on the System

LSA flapping or a route calculation error may occur.

Possible Causes

This object indicates that the aging time of a received LSA is greater than 1800s.

Procedure

1. Run the display ospf lsdb command to check whether the value of the Age field is less than 1800s.

  • If the value of the Age field is greater than or equal to 1800s, check whether the value was changed manually.
  • If the value of the Age field was changed manually, no action is required, and go to Step 3.
  • If the value of the Age field was not changed manually, go to Step 2.
  • If the value of the Age field is less than 1800s, go to Step 2.

2. Collect alarm information and configuration information, and then contact technical support personnel.

3. End.