BIP8 SD alarm. (hwPhysicalPortIfIndex=[hwPhysicalPortIfIndex],hwPhysicalPortName="[hwPhysicalPortName]",hwPhysicalPortBIP8SDErrorThreshold=[hwPhysicalPortBIP8SDErrorThreshold])
BIP8 SD alarm.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Critical |
Mnemonic Code |
hwPhysicalPortBip8SdError |
Trap OID |
1.3.6.1.4.1.2011.5.25.157.2.157.7 |
MIB |
HUAWEI-PORT-MIB |
Alarm ID |
0x0813008e |
Alarm Name |
hwPhysicalPortBip8SdError |
Alarm Type |
equipmentAlarm |
Raise or Clear |
Raise |
Match trap |
PIC_1.3.6.1.4.1.2011.5.25.157.2.157.8 hwPhysicalPortBip8SdErrorResume |
Parameter | Description |
---|---|
hwPhysicalPortIfIndex |
Index of physical port. |
hwPhysicalPortName |
Name of physical port. |
hwPhysicalPortBIP8SDErrorThreshold |
BIP8-SD error alarm threshold. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.157.1.14.1.1.1 |
hwPhysicalPortThrIfIndex |
hwPhysicalPortThrIfIndex |
1.3.6.1.4.1.2011.5.25.157.1.14.1.1.2 |
hwPhysicalPortThrName |
hwPhysicalPortThrIfIndex |
1.3.6.1.4.1.2011.5.25.157.1.14.1.1.23 |
hwPhysicalPortBIP8SDErrorThreshold |
hwPhysicalPortThrIfIndex |
1.Replace the optical module and check whether the alarm is cleared.
2.Replace the optical fiber and check whether the alarm is cleared.
3.Collect alarm information, log information and configuration information, and then contact technical support personnel.
4.End.