PIC_1.3.6.1.4.1.2011.5.25.157.2.157.7 hwPhysicalPortBip8SdError

Trap Buffer Description

BIP8 SD alarm. (hwPhysicalPortIfIndex=[hwPhysicalPortIfIndex],hwPhysicalPortName="[hwPhysicalPortName]",hwPhysicalPortBIP8SDErrorThreshold=[hwPhysicalPortBIP8SDErrorThreshold])

BIP8 SD alarm.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Critical

Mnemonic Code

hwPhysicalPortBip8SdError

Trap OID

1.3.6.1.4.1.2011.5.25.157.2.157.7

MIB

HUAWEI-PORT-MIB

Alarm ID

0x0813008e

Alarm Name

hwPhysicalPortBip8SdError

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

PIC_1.3.6.1.4.1.2011.5.25.157.2.157.8 hwPhysicalPortBip8SdErrorResume

Trap Buffer Parameters

Parameter Description

hwPhysicalPortIfIndex

Index of physical port.

hwPhysicalPortName

Name of physical port.

hwPhysicalPortBIP8SDErrorThreshold

BIP8-SD error alarm threshold.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.157.1.14.1.1.1

hwPhysicalPortThrIfIndex

hwPhysicalPortThrIfIndex

1.3.6.1.4.1.2011.5.25.157.1.14.1.1.2

hwPhysicalPortThrName

hwPhysicalPortThrIfIndex

1.3.6.1.4.1.2011.5.25.157.1.14.1.1.23

hwPhysicalPortBIP8SDErrorThreshold

hwPhysicalPortThrIfIndex

Impact on the System

Data of some services on the interface will be dropped.

Possible Causes

  • Cause 0: The optical module failed.
  • Cause 1: The optical fiber failed.

Procedure

1.Replace the optical module and check whether the alarm is cleared.

  • If the alarm is cleared, go to End.
  • If the alarm persists, go to Step 2.

2.Replace the optical fiber and check whether the alarm is cleared.

  • If the alarm is cleared, go to End.
  • If the alarm persists, go to Step 3.

3.Collect alarm information, log information and configuration information, and then contact technical support personnel.

4.End.