The status of the physical interface is Down. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=144384, ReasonDescription=[hwPortDownReason])
The status of the physical interface is Down.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Alert |
Mnemonic Code |
hwPortDown |
Trap OID |
1.3.6.1.4.1.2011.5.25.219.2.12.1 |
MIB |
HUAWEI-ENTITY-TRAP-MIB |
Alarm ID |
0x0813005b |
Alarm Name |
hwPortDown |
Alarm Type |
equipmentAlarm |
Raise or Clear |
Raise |
Match trap |
Parameter | Description |
---|---|
EntityPhysicalIndex |
Index of the physical entity. |
EntPhysicalIndex |
Index of physical port. |
EntPhysicalName |
Name of the physical entity. |
EntityTrapFaultID |
Error code. |
hwPortDownReason |
Indicates the description of the possible cause. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.219.1.1 |
hwEntityPhysicalIndex |
- |
1.3.6.1.2.1.47.1.1.1.1.7 |
entPhysicalName |
entPhysicalIndex |
1.3.6.1.4.1.2011.5.25.219.1.3 |
hwEntityTrapFaultID |
- |
1.3.6.1.4.1.2011.5.25.219.1.11 |
hwPortDownReason |
- |
1.3.6.1.2.1.2.2.1.8 |
ifOperStatus |
- |
1.3.6.1.2.1.2.2.1.7 |
ifAdminStatus |
- |
1. Check the link between failure port and peer port to make sure the link is normal. Check whether the fault is rectified.
2. Run the display interface interface-type interface-number command in the user view to check the status of failure port and peer port.
3. If the failure port or peer port is in managing down status, then enter the interface view and run the undo shutdown command. Check whether the fault is rectified
4. Collect alarm information, log information and configuration information, and then contact technical support personnel.
5. End.