PIC_1.3.6.1.4.1.2011.5.25.219.2.12.1 hwPortDown-144384

Trap Buffer Description

The status of the physical interface is Down. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=144384, ReasonDescription=[hwPortDownReason])

The status of the physical interface is Down.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwPortDown

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.12.1

MIB

HUAWEI-ENTITY-TRAP-MIB

Alarm ID

0x0813005b

Alarm Name

hwPortDown

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

PIC_1.3.6.1.4.1.2011.5.25.219.2.12.2 hwPortUp-144384

Trap Buffer Parameters

Parameter Description

EntityPhysicalIndex

Index of the physical entity.

EntPhysicalIndex

Index of physical port.

EntPhysicalName

Name of the physical entity.

EntityTrapFaultID

Error code.

hwPortDownReason

Indicates the description of the possible cause.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.219.1.1

hwEntityPhysicalIndex

-

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.3

hwEntityTrapFaultID

-

1.3.6.1.4.1.2011.5.25.219.1.11

hwPortDownReason

-

1.3.6.1.2.1.2.2.1.8

ifOperStatus

-

1.3.6.1.2.1.2.2.1.7

ifAdminStatus

-

Impact on the System

Traffic forwarding on the physical interface will be affected. Thus, a speedy solution is required.

Possible Causes

The status of the physical interface is Down.

Procedure

1. Check the link between failure port and peer port to make sure the link is normal. Check whether the fault is rectified.

  • If so, go to Step 5.
  • If not, go to Step 2.

2. Run the display interface interface-type interface-number command in the user view to check the status of failure port and peer port.

3. If the failure port or peer port is in managing down status, then enter the interface view and run the undo shutdown command. Check whether the fault is rectified

  • If so, go to Step 5.
  • If not, go to Step 4.

4. Collect alarm information, log information and configuration information, and then contact technical support personnel.

5. End.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.