PIC_1.3.6.1.4.1.2011.5.25.219.2.3.5 hwCardInvalid-135425

Trap Buffer Description

The card failed completely. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityType=[EntityType], EntityTrapFaultID=135425, ReasonDescription=The FPGA logic of the subcard was faulty.)

The card failed completely.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwCardInvalid

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.3.5

MIB

HUAWEI-ENTITY-TRAP-MIB

Alarm ID

0x08130057

Alarm Name

hwCardInvalid

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

PIC_1.3.6.1.4.1.2011.5.25.219.2.3.6 hwCardInvalidResume-135425

Trap Buffer Parameters

Parameter Description

EntityPhysicalIndex

Indicates the index of the physical entity.

EntPhysicalIndex

Indicates the index of the physical entity.

EntityTrapFaultID

Indicates the error code.

EntPhysicalName

Indicates the name of the physical entity.

EntityType

Indicates the type of the physical entity.

ReasonDescription

Indicates the description of the cause of the trap.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.219.1.1

hwEntityPhysicalIndex

-

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.2

hwEntityTrapEntType

-

1.3.6.1.4.1.2011.5.25.219.1.3

hwEntityTrapFaultID

-

1.3.6.1.4.1.2011.5.25.219.1.13

hwEntityTrapReasonDescr

-

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.2

hwEntityOperStatus

entPhysicalIndex

Impact on the System

The subcard cannot be used and all services on the subcard will fail. This requires an immediate action.

Possible Causes

The FPGA logic of the subcard was faulty.

Procedure

1.If the motherboard on which the subcard resides does not support FPIC, go to Step 5.

2.If the motherboard on which the subcard resides resets, no action is required.

3.Power off the subcard and then power it on again.

4.If the subcard cannot be registered or the alarm persists after the subcard is registered, replace the subcard.

5.If the motherboard supports only one subcard, power off the motherboard and then power it on again.

6.If the motherboard does not support FPIC, and the motherboard cannot be registered or the alarm persists after the motherboard is registered, replace the motherboard.

7.If the motherboard supports FPIC, and the motherboard cannot be registered or the alarm persists after the motherboard is registered, replace the subcard. If the fault persists, replace the motherboard.

8.Collect the information about alarms, logs, and configurations, and then contact technical support personnel.