PIM_1.3.6.1.4.1.2011.5.25.149.4.0.36 hwPimRpfAssertWinnerFlapping

Trap Buffer Description

The assert winner is flapping. (AddressFamily=[AddressFamily], SrcAddr=[SrcAddr], GrpAddr=[GrpAddr], InterfaceName=[InterfaceName], CurrentAssertWinnerAddr=[CurrentAssertWinnerAddr], InstanceName=[InstanceName])

The assert winner flapped.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Error

Mnemonic Code

PIM_RPF_ASST_WINNER_FLAPPING

Trap OID

1.3.6.1.4.1.2011.5.25.149.4.0.36

MIB

HUAWEI-PIM-STD-MIB

Alarm ID

0x00F102c6

Alarm Name

PIM_RPF_ASSERT_WINNER_FLAPPING

Alarm Type

communicationsAlarm

Raise or Clear

Raise

Match trap

PIM_1.3.6.1.4.1.2011.5.25.149.4.0.37 hwPimRpfAssertWinnerFlappingClear

Trap Buffer Parameters

Parameter Description

AddressFamily

Address family.

SrcAddr

Multicast source address.

GrpAddr

Multicast group address.

InterfaceName

Interface name.

CurrentAssertWinnerAddr

Current assert winner address.

InstanceName

Instance name.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.149.4.1.62

hwPimNotificationAddressType

-

1.3.6.1.4.1.2011.5.25.149.4.1.69

hwPimNotificationSrcAddr

-

1.3.6.1.4.1.2011.5.25.149.4.1.70

hwPimNotificationGrpAddr

-

1.3.6.1.4.1.2011.5.25.149.4.1.1.1.29

hwPimInterfaceName

hwPimInterfaceIfIndex

hwPimInterfaceIpVersion

1.3.6.1.4.1.2011.5.25.149.4.1.83

hwPimNotificationAssertWinnerAddress

-

1.3.6.1.4.1.2011.5.25.149.4.1.60

hwPimInstanceName

-

Impact on the System

Data forwarding services will be affected by packet loss.

Possible Causes

The Assert status of the downstream interface of the upstream device changes frequently

Procedure

1. Run the display pim routing-table fsm command or the display pim ipv6 routing-table fsm command to check whether the ASSERT status is normal.

  • If the status is normal, go to step 3.
  • If the status is not normal, go to step 2.

2. Run the display pim control-message counters or display pim ipv6 control-message counters to check whether the ASSERT packets are sent and received normally.

  • If the transmission and reception is normal, go to step 3.
  • If the transmission and reception is not normal, rectify the fault to clear the alarm.

3. Collect alarm and configuration information, and then contact technical support personnel.