PIM_1.3.6.1.4.1.2011.5.25.149.4.0.5 interface-election

Trap Buffer Description

The interface is elected as a DR. (IfIndex=[IfIndex], IfName=[PimInterfaceName], IfIPverion=[IfIPverion], IfAddrType=[IfAddrType], Addr=[Addr], PimInstanceID=[PimInstanceID], PimInstanceName=[PimInstanceName])

The interface is elected as a DR.

Trap Attributes

Trap Attribute Description

Alarm or Event

Event

Trap Severity

Warning

Mnemonic Code

HW_DR_ELECTION

Trap OID

1.3.6.1.4.1.2011.5.25.149.4.0.5

MIB

HUAWEI-PIM-STD-MIB

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Name

This is an event trap and does not involve alarm name.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

-

Trap Buffer Parameters

Parameter Description

IfIndex

Interface index.

PimInterfaceName

Interface name.

IfIPverion

IP version of the interface.

IfAddrType

Interface address type.

Addr

Interface address.

PimInstanceID

VPN instance ID.

PimInstanceName

VPN instance name.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.149.4.1.1.1.3

hwPimInterfaceAddressType

hwPimInterfaceIfIndex

hwPimInterfaceIpVersion

1.3.6.1.4.1.2011.5.25.149.4.1.1.1.4

hwPimInterfaceAddress

hwPimInterfaceIfIndex

hwPimInterfaceIpVersion

1.3.6.1.4.1.2011.5.25.149.4.1.1.1.29

hwPimInterfaceName

hwPimInterfaceIfIndex

hwPimInterfaceIpVersion

1.3.6.1.4.1.2011.5.25.149.4.1.57

hwPimInstanceID

-

1.3.6.1.4.1.2011.5.25.149.4.1.60

hwPimInstanceName

-

Impact on the System

If the source-side DR changes, the RP receives an incorrect Register message; if the member-side DR changes, the RP receives an incorrect Join message.

Possible Causes

Cause1: The PIM interface received a new Hello packet and had a higher DR priority or IP address than other interfaces on the shared network segment.

Cause2: After a PIM interface went Up, the PIM interface did not receive Hello packets after the interval between Hello packets expired.

Procedure

  • Check whether the interface that is elected as a DR is the desired one. If the interface is not the desired one, configure a lower DR priority or a lower IP address for the interface.
Copyright © Huawei Technologies Co., Ltd.