The SDH B1 error is rising. (hwIfMonitorIndex=[hwIfMonitorIndex], hwIfMonitorSdhB1ErrorStatistics=[hwIfMonitorSdhB1ErrorStatistics], hwIfMonitorSdhB1ErrorThreshold=[hwIfMonitorSdhB1ErrorThreshold], hwIfMonitorSdhB1ErrorInterval=[hwIfMonitorSdhB1ErrorInterval],hwIfMonitorName=[hwIfMonitorName])
The number of SDH B1 errors exceeded the preconfigured threshold in a specified period.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Critical |
Mnemonic Code |
hwIfMonitorSdhB1ErrorRising |
Trap OID |
1.3.6.1.4.1.2011.5.25.41.4.14 |
MIB |
HUAWEI-IF-EXT-MIB |
Alarm ID |
0x0813213f |
Alarm Name |
hwIfMonitorSdhB1ErrorRising |
Alarm Type |
communicationsAlarm |
Raise or Clear |
Raise |
Match trap |
PORT_1.3.6.1.4.1.2011.5.25.41.4.15 hwIfMonitorSdhB1ErrorResume |
Parameter | Description |
---|---|
hwIfMonitorIndex |
Index of physical port. |
hwIfMonitorSdhB1ErrorStatistics |
Statistics about SDH B1 bit errors. |
hwIfMonitorSdhB1ErrorThreshold |
Maximum number of SDH B1 bit errors. |
hwIfMonitorSdhB1ErrorInterval |
Period during which the number of SDH B1 bit errors is counted. |
hwIfMonitorName |
Name of physical port. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.41.1.7.1.1.20 |
hwIfMonitorSdhB1ErrorStatistics |
hwIfMonitorIndex |
1.3.6.1.4.1.2011.5.25.41.1.7.1.1.21 |
hwIfMonitorSdhB1ErrorThreshold |
hwIfMonitorIndex |
1.3.6.1.4.1.2011.5.25.41.1.7.1.1.22 |
hwIfMonitorSdhB1ErrorInterval |
hwIfMonitorIndex |
1.3.6.1.4.1.2011.5.25.41.1.7.1.1.19 |
hwIfMonitorName |
hwIfMonitorIndex |
1.Check whether the link (optical fiber, optic module, transmission device, jumper frame, etc) is faulty.
2.Replace the faulty component and correctly connect the link, and check whether the alarm hwIfMonitorSdhB1ErrorResume is displayed.
3.Collect alarm information, log information and configuration information, and then contact technical support personnel.