PORT_1.3.6.1.4.1.2011.5.25.41.4.16 hwIfMonitorSdhB2ErrorRising

Trap Buffer Description

The SDH B2 error is rising. (hwIfMonitorIndex=[hwIfMonitorIndex], hwIfMonitorSdhB2ErrorStatistics=[hwIfMonitorSdhB2ErrorStatistics], hwIfMonitorSdhB2ErrorThreshold=[hwIfMonitorSdhB2ErrorThreshold], hwIfMonitorSdhB2ErrorInterval=[hwIfMonitorSdhB2ErrorInterval], hwIfMonitorName=[hwIfMonitorName])

The number of SDH B2 errors exceeded the preconfigured threshold in a specified period.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Critical

Mnemonic Code

hwIfMonitorSdhB2ErrorRising

Trap OID

1.3.6.1.4.1.2011.5.25.41.4.16

MIB

HUAWEI-IF-EXT-MIB

Alarm ID

0x08132140

Alarm Name

hwIfMonitorSdhB2ErrorRising

Alarm Type

communicationsAlarm

Raise or Clear

Raise

Match trap

PORT_1.3.6.1.4.1.2011.5.25.41.4.17 hwIfMonitorSdhB2ErrorResume

Trap Buffer Parameters

Parameter Description

hwIfMonitorIndex

Index of physical port.

hwIfMonitorSdhB2ErrorStatistics

Statistics about SDH B2 bit errors.

hwIfMonitorSdhB2ErrorThreshold

Maximum number of SDH B2 bit errors.

hwIfMonitorSdhB2ErrorInterval

Period during which the number of SDH B2 bit errors is counted.

hwIfMonitorName

Name of physical port.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.41.1.7.1.1.23

hwIfMonitorSdhB2ErrorStatistics

hwIfMonitorIndex

1.3.6.1.4.1.2011.5.25.41.1.7.1.1.24

hwIfMonitorSdhB2ErrorThreshold

hwIfMonitorIndex

1.3.6.1.4.1.2011.5.25.41.1.7.1.1.25

hwIfMonitorSdhB2ErrorInterval

hwIfMonitorIndex

1.3.6.1.4.1.2011.5.25.41.1.7.1.1.19

hwIfMonitorName

hwIfMonitorIndex

Impact on the System

Packet loss occurs on an interface when the alarm is generated. As a result, services are affected.

Possible Causes

The link was of poor quality.

Procedure

1.Check whether the link (optical fiber, optic module, transmission device, jumper frame, etc) is faulty.

  • If the link is faulty, go to Step 2.
  • If the link is normal, go to Step 3.

2.Replace the faulty component and correctly connect the link, and check whether the alarm hwIfMonitorSdhB2ErrorResume is displayed.

  • If the alarm is displayed, go to End.