Current lock status of clock frequency synchronization failed. (hwPtpFreqLockStatus=[hwPtpFreqLockStatus])
Frequency out-of-lock alarm.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Critical |
Mnemonic Code |
hwPtpFrequencyLockFail |
Trap OID |
1.3.6.1.4.1.2011.5.25.187.5.17 |
MIB |
HUAWEI-PTP-MIB |
Alarm ID |
0x09af000c |
Alarm Name |
hwPtpFrequencyLockFail |
Alarm Type |
equipmentAlarm |
Raise or Clear |
Raise |
Match trap |
Parameter | Description |
---|---|
hwPtpFreqLockStatus |
Frequency locking status of the clock. The values are as follows: unlock(0). lock(1). |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.187.1.88 |
hwPtpFreqLockStatus |
- |
Cause 1: During frequency synchronization based on synchronous Ethernet, the reference frequency source has an excessive frequency deviation.
Cause 2: During frequency synchronization based on IEEE 1588v2, timestamps are incorrect.
Cause 3: The DSP internal frequency control word exceeds +/-10 ppm.
1. Run the display clock source command to check whether the clock synchronization source is a PTP source, that is, whether the value of Current system trace source is ptp.
2. Run the display current-configuration command to check whether PTP configurations are changed.
3. Run the display clock config command to check whether the clock source configuration is changed.
4. Collect trap, log, and configuration information, and contact Huawei technical support personnel.
5. Ends.