PTP_1.3.6.1.4.1.2011.5.25.187.5.19 hwPtpExtTimePortLost

Trap Buffer Description

The external Time Port status changed. (hwPtpExtTimePortStatus=[hwPtpExtTimePortStatus], hwPtpExtTimePortType=[hwPtpExtTimePortType])

A alarm indicating that the external time source was lost was generated.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwPtpExtTimePortLost

Trap OID

1.3.6.1.4.1.2011.5.25.187.5.19

MIB

HUAWEI-PTP-MIB

Alarm ID

0x09af000d

Alarm Name

hwPtpExtTimePortLost

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

PTP_1.3.6.1.4.1.2011.5.25.187.5.20 hwPtpExtTimePortLostResume

Trap Buffer Parameters

Parameter Description

hwPtpExtTimePortStatus

Port status of the external Time. The value can be normal(0) or portDown(1).

hwPtpExtTimePortType

Port type of the external Time. The value can be bits0(0), bits1(1), bits2(2), bits1slot4(1025), bits1slot5(1281), bits1slot6(1537), bits1slot7(1793), bits1slot8(2049), bits1slot9(2305), bits1slot10(2561), bits1slot11(2817), bits1slot12(3073), bits1slot15(3841), bits1slot16(4097), bits1slot17(4353), bits1slot18(4609), bits1slot19(4865), bits1slot20(5121), bits1slot21(5377), bits1slot22(5633), bits1slot30(7681), or bits1slot31(7937).

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.187.1.89

hwPtpExtTimePortStatus

-

1.3.6.1.4.1.2011.5.25.187.1.90

hwPtpExtTimePortType

-

Impact on the System

The external time port cannot be used normally.

Possible Causes

Cause 1: The physical link carried over the external time port is down.

Cause 2: Different time formats are specified for the external time ports on the upstream and downstream devices.

Procedure

1. Check the physical link of external time port whether is up.

  • If so, go to step 3.
  • If not, go to step 2.

2. Analyze the reason of the physical link down, check whether the connection has been torn down, and fix the link. Then check whether there is a clear alarm.

  • If so, go to step 6.
  • If not, go to step 5.

3. Check the format of time port is upstream and downstream equipment outside the time port configuration whether are match.

  • If so, go to step 5.
  • If not, go to step 4.

4. Correctly configure the time format of time ports, for the configuration procedure,see the HUAWEI Universal Service Router Configuration Guide - System Management. - If incorrect,please re-configure. then check whether there is a clear alarm.

  • If so, go to step 6.
  • If not, go to step 5.

5. Collect the alarm information, log information, and configuration information, and then contact Huawei technical support personnel.

6. End.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >