PTP_1.3.6.1.4.1.2011.5.25.187.5.24 hwPtpAcrSyncBad

Trap Buffer Description

1588 ACR synchronization state is bad. (State=[State])

The synchronization of 1588 ACR clock is bad.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwPtpAcrSyncBad

Trap OID

1.3.6.1.4.1.2011.5.25.187.5.24

MIB

HUAWEI-PTP-MIB

Alarm ID

0x09af0012

Alarm Name

hwPtpAcrSyncBad

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

PTP_1.3.6.1.4.1.2011.5.25.187.5.25 hwPtpAcrSyncBadResume

Trap Buffer Parameters

Parameter Description

State

State of synchoronization. values:

normal(0).

abnormal(1).

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.187.1.106

hwPtpAcrSyncBadStatus

-

Impact on the System

The 1588 ACR recovery performance will deteriorate.

Possible Causes

Cause 1: The frequency offset of the traced source in synchronization Ethernet was too great.

Cause 2: The received timestamp was incorrect in 1588v2 frequency synchronization mode.

Cause 3: The DSP internal frequency control word exceeded +/-10 ppm.

Procedure

1. Run the display clock source command to check whether the current system trace source is PTP.

  • If the current system trace source is PTP, go to step 2.
  • If the current system trace source is not PTP, go to step 4.

2. Run the display current-configuration command to check whether PTP configurations need to be changed.

  • If PTP configurations need to be changed, go to step 3.
  • If PTP configurations do not need to be changed, go to step 6.

3. Reconfigure the local PTP attributes. Then check whether the alarm is cleared.

  • If the alarm is cleared, go to step 7.
  • If the alarm persists, go to step 6.

4. Run the display clock config command to check whether clock source configurations need to be changed.

  • If clock source configurations need to be changed, go to step 5.
  • If clock source configurations do not need to be changed, go to step 6.

5. Reconfigure the local clock source attributes. Then check whether the alarm is cleared.

  • If the alarm is cleared, go to step 7.
  • If the alarm persists, go to step 6.

6. Collect the alarm information, log information, and configuration information, and contact Huawei technical support personnel.

7. End.