PTP_1.3.6.1.4.1.2011.5.25.187.5.37 hwPtpTimeOffsetSumOver

Trap Buffer Description

The ptp time offset sum is abnormal. (hwPtpTimeOffsetSumP2P=[hwPtpTimeOffsetSumP2P], hwPtpAlarmThresholdOffsetSum=[hwPtpAlarmThresholdOffsetSum])

The accumulated PTP time offsets exceeded threshold.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Error

Mnemonic Code

hwPtpTimeOffsetSumOver

Trap OID

1.3.6.1.4.1.2011.5.25.187.5.37

MIB

HUAWEI-PTP-MIB

Alarm ID

0x00F1006b

Alarm Name

hwPtpTimeOffsetSumOver

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

PTP_1.3.6.1.4.1.2011.5.25.187.5.38 hwPtpTimeOffsetSumOverResume

Trap Buffer Parameters

Parameter Description

hwPtpTimeOffsetSumP2P

Accumulated and peak time offset values.

hwPtpAlarmThresholdOffsetSum

Threshold of the sum of time offset.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.187.1.129

hwPtpTimeOffsetSumP2P

-

1.3.6.1.4.1.2011.5.25.187.1.128

hwPtpAlarmThresholdOffsetSum

-

Impact on the System

The device fails to properly lock the time source.

Possible Causes

The accumulated value of the time offset used for system clock adjustment within 15 minutes plus the peak value is out of the specified value range.

Procedure

1. Check whether the current time is locked.

  • If so, go to Step 3.
  • If not, go to Step 2.

2. Wait for 5 minutes and check whether the time is locked.

  • If so, go to Step 3.
  • If not, go to Step 4.

3. Wait for 5 minutes and check whether the alarm is cleared.

  • If so, go to Step 5.
  • If not, go to Step 4.

4. Collect alarm, log, and configuration information, and contact Huawei technical support personnel.

5. End.