PTP_1.3.6.1.4.1.2011.5.25.187.5.3 hwPtpTimeSyncFaulty

Trap Buffer Description

Time source traced status is faulty. (hwPtpTimeSynchronizationStatus=[hwPtpTimeSynchronizationStatus])

This alarm was generated when the device was unsynchronized with master clock.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwPtpTimeSyncFaulty

Trap OID

1.3.6.1.4.1.2011.5.25.187.5.3

MIB

HUAWEI-PTP-MIB

Alarm ID

0x09af0009

Alarm Name

hwPtpTimeSyncFaulty

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

PTP_1.3.6.1.4.1.2011.5.25.187.5.4 hwPtpTimeSyncResume

Trap Buffer Parameters

Parameter Description

hwPtpTimeSynchronizationStatus

Indicate that the status of the equipment is

synchronization or unsynchoronization. The value can be:

unsynchoronization(1).

synchoronization(2).

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.187.1.22

hwPtpTimeSynchronizationStatus

-

Impact on the System

The device cannot synchronized to master clock.

Possible Causes

Cause1: The link was faulty or the interface went Down, and as a result, the device failed to keep track of the clock source.

Cause2: The priority of the local device was set so high that the local device is in local state, and it will not trace other clock source.

Procedure

1. Run the display device command to check whether the interface board can properly register.

If the interface board fails to register, the board hardware is faulty. Replace the board.

If the interface board can properly register after being reset, and no link fault has occurred, go to Step 2.

2. Run the display ptp all command to check whether the device is in the local state.

If so, go to Step 3.

If not, go to Step 6.

3. Run the display ptp all command to check whether the external BITS status is normal.

If so, go to Step 4.

If not, go to Step 6.

4. Run the ptp clock-source local priority1 priority1-value command to correctly configure clock attributes for the device.

5. After the configuration is complete, run the display ptp all command to check whether the device is still in the local state.

If so, go to Step 6.

If not, go to Step 7.

6. Collect trap, log, and configuration information, and contact Huawei technical support personnel.

7. End.