PTP_1.3.6.1.4.1.2011.5.25.187.5.52 hwPtpaPortStateChange

Trap Buffer Description

The port status changes. (hwPtpaVPortId=[hwPtpaVPortId], hwPtpaPortState=[hwPtpaPortState], hwPtpaOldPortState=[hwPtpaOldPortState])

This alarm is generated when port status changes.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Event

Trap Severity

Warning

Mnemonic Code

hwPtpaPortStateChange

Trap OID

1.3.6.1.4.1.2011.5.25.187.5.52

MIB

HUAWEI-PTP-MIB

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Name

This is an event trap and does not involve alarm name.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

-

Trap Buffer Parameters

Parameter Description

hwPtpaVPortId

Specifies the port ID.

hwPtpaPortState

Specifies the interface status.

hwPtpaOldPortState

Specifies the old port status.

The value can be:

master(0)

slave(1)

passive(2)

listening(3)

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.187.11.1.1.1

hwPtpaVPortId

hwPtpaVPortId

1.3.6.1.4.1.2011.5.25.187.11.1.1.2

hwPtpaPortState

hwPtpaVPortId

1.3.6.1.4.1.2011.5.25.187.11.1.1.3

hwPtpaOldPortState

hwPtpaVPortId

Impact on the System

The optimal time source may be switched.

Possible Causes

Cause 1: The attributes of the time source, optimal source, and local time source change. As a result, the port status changes.

Cause 2: The link was faulty, causing the port status to change.

Cause 3: The device was restarted, causing the interface status to change.

Procedure

1. Run the display interface brief command to check whether the interface is Down.

If yes, the link is faulty. In this case, go to step 5.

If no, go to Step 2.

2. Run the display this interface and display ptp-adaptive vport commands to check whether the command for changing the clock attribute of the port is configured.

If yes, the clock attribute changes. In this case, go to step 5.

If not, go to step 3.

3. Run the display board-reset all command in the diagnostic view to check the last MPU restart time and collect alarm information.

If the fault occurs after the device is restarted, the port status changes due to the device restart. In this case, go to Step 5.

If not, go to Step 4.

4. Collect trap, log, and configuration information, and contact Huawei technical support personnel.

5. End.