The TCP connection of RBS was torn down. (RBS name=[RbsName], Down reason=[RbsDownReason])
The TCP connection of the RBS was turn down.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Warning |
Mnemonic Code |
hwRbsDown |
Trap OID |
1.3.6.1.4.1.2011.5.2.2.2.0.7 |
MIB |
HUAWEI-AAA-MIB |
Alarm ID |
0x00F100ff |
Alarm Name |
hwRbsDown |
Alarm Type |
communicationsAlarm |
Raise or Clear |
Raise |
Match trap |
Parameter | Description |
---|---|
RbsName |
Name of the RBS |
RbsDownReason |
Reason that the TCP connection of the RBS was torn down |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.2.2.1.12 |
hwRbsName |
- |
1.3.6.1.4.1.2011.5.2.2.1.13 |
hwRbsDownReason |
- |
1.Run the display this command in the RBS view to check whether the shutdown configuration exists.
2.Run the display remote-backup-service command on two devices that back up each other to check RBS information.
The local IP address of the local device must be the same as the peer IP address of the backup device.
The peer IP address of the local device must be the same as the local IP address of the backup device.
The same port number must be configured for the TCP connections on the two devices that back up each other.
Check whether the following conditions are met:
3.Run the peer peer-ip-address source source-ip-address port port-id command to reconfigure TCP connection parameters for the RBS.
4.Run the ping command to check whether the peer device is reachable.
5.Collect the trap, log, and configuration information, and then contact Huawei technical support personnel.
6.End.
The same as Cause 1.
The same as Cause 1.
The same as Cause 1.