SFLOW_1.3.6.1.4.1.2011.5.25.368.1.2.1 hwSFlowUnsupportedBoard

Trap Buffer Description

The board doesn't support sFlow. (Slot=[hwSFlowEnSlot])

The board does not support sFlow.

In VS mode, this trap is supported only by the admin VS.

This alarm is supported only on NetEngine 8000 F1A.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwSflowUnsupportedBoard

Trap OID

1.3.6.1.4.1.2011.5.25.368.1.2.1

MIB

HUAWEI-SFLOW-MIB

Alarm ID

0x00f10479

Alarm Name

hwSFlowUnsupportedBoard

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

SFLOW_1.3.6.1.4.1.2011.5.25.368.1.2.2 hwSFlowUnsupportedBoardResume

Trap Buffer Parameters

Parameter Description

hwSFlowEnSlot

Slot ID.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.368.1.1.1

hwSFlowEnSlot

-

Impact on the System

The sFlow configuration in the slot view does not take effect.

Possible Causes

sFlow is enabled in the slot view of the board that does not support sFlow.

Procedure

1. Check whether the card supports sFlow based on the slot ID in the alarm information.

2. Replace the card with one that supports sFlow or delete the sFlow configuration in the slot view. Check whether the alarm is cleared.

  • If the alarm is cleared, go to Step 4.
  • If the alarm persists, go to Step 3.

3. Collect trap, log, and configuration information, and contact technical support personnel.

4. The procedure ends.