SNMP_1.3.6.1.4.1.2011.5.25.164.3.3 hwSNMPReset

Trap Buffer Description

SNMP was switched to a new process.

The SNMP process was restarted or a master/slave main control board switchover was performed on a device. The corresponding trap was sent to notify the NMS of SNMP entity restart, enabling the NMS to synchronize alarms from the device.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Event

Trap Severity

Warning

Mnemonic Code

SNMP_RESET

Trap OID

1.3.6.1.4.1.2011.5.25.164.3.3

MIB

HUAWEI-SNMP-EXT-MIB

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Name

This is an event trap and does not involve alarm name.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

-

Trap Buffer Parameters

None

VB Parameters

None

Impact on the System

The system will not be affected.

Possible Causes

The SNMP process was restarted or a master/slave main control board switchover was performed on a device.

Procedure

This trap message is informational only, and no action is required.
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.