A system configuration error occurs. ( EntityTrapFaultID = [EntityTrapFaultID])
The system configuration is incorrect.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Critical |
Mnemonic Code |
hwSystemConfigError |
Trap OID |
1.3.6.1.4.1.2011.5.25.219.2.11.1 |
MIB |
HUAWEI-ENTITY-TRAP-MIB |
Alarm ID |
0x0D300004 |
Alarm Name |
hwSystemConfigError |
Alarm Type |
equipmentAlarm |
Raise or Clear |
Raise |
Match trap |
SYSTEM_1.3.6.1.4.1.2011.5.25.219.2.11.2 hwSystemConfigResume-144130 |
Parameter | Description |
---|---|
EntityTrapFaultID |
Trap error code:
|
None
The versions of the active and standby boards are inconsistent.
1. Run the startup system-software command to change the version of the slave board to be the same as that of the master board. Then, run the reset slot command to reset the slave board.
2. Collect alarm and configuration information, and contact technical support personnel.
3. No further action is required.