TPM_1.3.6.1.4.1.2011.5.25.19.2.31 hwTpmChipFault

Trap Buffer Description

A TPM chip fault occurred on a board.(PhysicalIndex=[PhysicalIndex], PhysicalName=[PhysicalName])

TPM chip fault alarm.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwTpmChipStatusAlarm

Trap OID

1.3.6.1.4.1.2011.5.25.19.2.31

MIB

HUAWEI-SYS-MAN-MIB

Alarm ID

0x0970200B

Alarm Name

hwTpmChipFault

Alarm Type

processingErrorAlarm

Raise or Clear

Raise

Match trap

TPM_1.3.6.1.4.1.2011.5.25.19.2.32 hwTpmChipFaultClear

Trap Buffer Parameters

Parameter Description

PhysicalIndex

Physical index.

PhysicalName

Name of an entity.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.2.1.47.1.1.1.1.1

entPhysicalIndex

entPhysicalIndex

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

Impact on the System

Measurement start function will not be affected.

Possible Causes

A TPM chip fault occurred on a board.

Procedure

For the hot swappable TPM chip, replace the faulty TPM chip on the card, and then restart the card.

If the TPM chip is not hot swappable, collect trap, log, and configuration information, and contact Huawei technical support.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
Next topic >