unexpected MEG alarm start. (MegId=[MegId], MegId=[Meg_Id], MeIndex=[MeIndex], MeType=[MeType], MeDirection=[MeDirection], IfName=[IfName], PeerIP=[PeerIP], VcId=[VcId], VcType=[VcType], RemoteIp=[RemoteIp], Ttl=[Ttl], MepId=[MepId], RemoteMepId=[RemoteMepId], LspName=[LspName], VsiName=[VsiName])
TP OAM detected that the MEG configurations on both ends were different.
Trap Attribute | Description |
---|---|
Alarm or Event |
Event |
Trap Severity |
Warning |
Mnemonic Code |
hwMplsTpOamUnExpectMeg |
Trap OID |
1.3.6.1.4.1.2011.5.25.235.1.5.5 |
MIB |
HUAWEI-TPOAM-MIB |
Alarm ID |
This is an event trap and does not involve alarm ID. |
Alarm Name |
This is an event trap and does not involve alarm name. |
Alarm Type |
This is an event trap and does not involve alarm type. |
Raise or Clear |
This is an event trap and does not involve alarm generation or clearance. |
Match trap |
- |
Parameter | Description |
---|---|
MegId |
Name of a MEG. |
Meg_Id |
Name of a MEG. |
MeIndex |
Index of an ME. |
MeType |
ME type:
|
MeDirection |
Tunnel type for an ME:
|
IfName |
Interface name. |
PeerIP |
Peer IP address. |
VcId |
VC ID. |
VcType |
VC type. |
RemoteIp |
IP address of an RMEP. |
Ttl |
TTL value. |
MepId |
Local ME ID. |
RemoteMepId |
RMEP ID. |
LspName |
LSP name. |
VsiName |
VSI name. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.235.1.1.1.1.1 |
hwMplsTpOamMegId |
hwMplsTpOamMegId |
1.3.6.1.4.1.2011.5.25.235.1.2.1.1.2 |
hwMplsTpOamMeType |
hwMplsTpOamMegId hwMplsTpOamMeIndex |
1.3.6.1.4.1.2011.5.25.235.1.2.1.1.3 |
hwMplsTpOamMeDirection |
hwMplsTpOamMegId hwMplsTpOamMeIndex |
1.3.6.1.4.1.2011.5.25.235.1.2.1.1.4 |
hwMplsTpOamMeIfName |
hwMplsTpOamMegId hwMplsTpOamMeIndex |
1.3.6.1.4.1.2011.5.25.235.1.2.1.1.5 |
hwMplsTpOamMePeerip |
hwMplsTpOamMegId hwMplsTpOamMeIndex |
1.3.6.1.4.1.2011.5.25.235.1.2.1.1.6 |
hwMplsTpOamMeVcId |
hwMplsTpOamMegId hwMplsTpOamMeIndex |
1.3.6.1.4.1.2011.5.25.235.1.2.1.1.7 |
hwMplsTpOamMeVcType |
hwMplsTpOamMegId hwMplsTpOamMeIndex |
1.3.6.1.4.1.2011.5.25.235.1.2.1.1.8 |
hwMplsTpOamMeVllRemotePeerIp |
hwMplsTpOamMegId hwMplsTpOamMeIndex |
1.3.6.1.4.1.2011.5.25.235.1.2.1.1.9 |
hwMplsTpOamMEVllTTL |
hwMplsTpOamMegId hwMplsTpOamMeIndex |
1.3.6.1.4.1.2011.5.25.235.1.2.1.1.10 |
hwMplsTpOamMeMepId |
hwMplsTpOamMegId hwMplsTpOamMeIndex |
1.3.6.1.4.1.2011.5.25.235.1.2.1.1.11 |
hwMplsTpOamMeRemoteMepId |
hwMplsTpOamMegId hwMplsTpOamMeIndex |
1.3.6.1.4.1.2011.5.25.235.1.2.1.1.13 |
hwMplsTpOamMeLspName |
hwMplsTpOamMegId hwMplsTpOamMeIndex |
1.3.6.1.4.1.2011.5.25.235.1.2.1.1.14 |
hwMplsTpOamMeVsiName |
hwMplsTpOamMegId hwMplsTpOamMeIndex |
1. Run the display current-configuration command to check whether the MEG configurations on both ends are the same.
2. Reconfigure the MEGs on the MEP and RMEP, and check whether the alarm is cleared.
3. Collect log information and configuration information, and then contact technical support personnel.
4. End.