TPOAM_1.3.6.1.4.1.2011.5.25.235.1.5.9 hwMplsTpOamUnExpectPeriod

Trap Buffer Description

unexpected period alarm start. (MegId=[MegId], MegId=[Meg_Id], MeIndex=[MeIndex], MeType=[MeType], MeDirection=[MeDirection], IfName=[IfName], PeerIP=[PeerIP], VcId=[VcId], VcType=[VcType], RemoteIp=[RemoteIp], Ttl=[Ttl], MepId=[MepId], RemoteMepId=[RemoteMepId], LspName=[LspName], VsiName=[VsiName])

TP OAM detected that the intervals at which both ends sent CCMs were different.

Trap Attributes

Trap Attribute Description

Alarm or Event

Event

Trap Severity

Warning

Mnemonic Code

hwMplsTpOamUnExpectPeriod

Trap OID

1.3.6.1.4.1.2011.5.25.235.1.5.9

MIB

HUAWEI-TPOAM-MIB

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Name

This is an event trap and does not involve alarm name.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

-

Trap Buffer Parameters

Parameter Description

MegId

Name of a MEG.

Meg_Id

Name of a MEG.

MeIndex

Index of an ME.

MeType

ME type:

  • 1: PW VLL
  • 2: PW VSI
  • 3: TE -CR LSP
  • 4: Section
  • 5: Associate.

MeDirection

Tunnel type for an ME:

  • ingress
  • egress
  • dual.

IfName

Interface name.

PeerIP

Peer IP address.

VcId

VC ID.

VcType

VC type.

RemoteIp

IP address of an RMEP.

Ttl

TTL value.

MepId

Local ME ID.

RemoteMepId

RMEP ID.

LspName

LSP name.

VsiName

VSI name.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.235.1.1.1.1.1

hwMplsTpOamMegId

hwMplsTpOamMegId

1.3.6.1.4.1.2011.5.25.235.1.2.1.1.2

hwMplsTpOamMeType

hwMplsTpOamMegId

hwMplsTpOamMeIndex

1.3.6.1.4.1.2011.5.25.235.1.2.1.1.3

hwMplsTpOamMeDirection

hwMplsTpOamMegId

hwMplsTpOamMeIndex

1.3.6.1.4.1.2011.5.25.235.1.2.1.1.4

hwMplsTpOamMeIfName

hwMplsTpOamMegId

hwMplsTpOamMeIndex

1.3.6.1.4.1.2011.5.25.235.1.2.1.1.5

hwMplsTpOamMePeerip

hwMplsTpOamMegId

hwMplsTpOamMeIndex

1.3.6.1.4.1.2011.5.25.235.1.2.1.1.6

hwMplsTpOamMeVcId

hwMplsTpOamMegId

hwMplsTpOamMeIndex

1.3.6.1.4.1.2011.5.25.235.1.2.1.1.7

hwMplsTpOamMeVcType

hwMplsTpOamMegId

hwMplsTpOamMeIndex

1.3.6.1.4.1.2011.5.25.235.1.2.1.1.8

hwMplsTpOamMeVllRemotePeerIp

hwMplsTpOamMegId

hwMplsTpOamMeIndex

1.3.6.1.4.1.2011.5.25.235.1.2.1.1.9

hwMplsTpOamMEVllTTL

hwMplsTpOamMegId

hwMplsTpOamMeIndex

1.3.6.1.4.1.2011.5.25.235.1.2.1.1.10

hwMplsTpOamMeMepId

hwMplsTpOamMegId

hwMplsTpOamMeIndex

1.3.6.1.4.1.2011.5.25.235.1.2.1.1.11

hwMplsTpOamMeRemoteMepId

hwMplsTpOamMegId

hwMplsTpOamMeIndex

1.3.6.1.4.1.2011.5.25.235.1.2.1.1.13

hwMplsTpOamMeLspName

hwMplsTpOamMegId

hwMplsTpOamMeIndex

1.3.6.1.4.1.2011.5.25.235.1.2.1.1.14

hwMplsTpOamMeVsiName

hwMplsTpOamMegId

hwMplsTpOamMeIndex

Impact on the System

A primary/secondary link switchover may be triggered.

Possible Causes

The intervals between sending CCMs were different on both ends.

Procedure

1. Run the display current-configuration command to check whether the intervals between sending CCMs on both ends are the same.

  • If they are the same, go to Step 3.
  • If they are different, go to Step 2.

2. Run the cc interval command to reconfigure the intervals between sending CCMs on both ends, and check whether the alarm is cleared.

  • If the alarm is cleared, go to Step 4.
  • If the alarm is not cleared, go to Step 3.

3. Collect log information and configuration information, and then contact technical support personnel.

4. End.