TUNNEL-TE_1.3.6.1.4.1.2011.5.12.7.1.4.5 hwMplsApsLost

Trap Buffer Description

Tunnel protection group did not receive APS frames from protection tunnel. (IfIndex=[WorkTunnelIfIndex], SessionTunnelId=[SessionTunnelId], LocalLspId=[LocalLspId], IngressLsrId=[IngressLsrId], EgressLsrId=[EgressLsrId], WorkTunnel=[WorkTunnel], SignalingProtocol=[SgnlPrtcl], SignalledTunnelName=[SignalledTunnelName])

No APS frame was transmitted on the protect tunnel in the tunnel protection group.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwMplsApsLost

Trap OID

1.3.6.1.4.1.2011.5.12.7.1.4.5

MIB

HUAWEI-MPLSOAM-MIB

Alarm ID

0x0001006a

Alarm Name

hwMplsApsLost

Alarm Type

communicationsAlarm

Raise or Clear

Raise

Match trap

TUNNEL-TE_1.3.6.1.4.1.2011.5.12.7.1.4.6 hwMplsApsLostRecovery

Trap Buffer Parameters

Parameter Description

SessionTunnelId

Indicates the tunnel ID.

LocalLspId

Indicates the local LSP ID.

IngressLsrId

Indicates the LSR ID of the ingress node.

EgressLsrId

Indicates the LSR ID of the egress node.

WorkTunnel

Indicates the name of the working tunnel in the protection group.

SgnlPrtcl

Indicates the tunnel protocol ID. The options are as follows:

  • 1: RSVP
  • 2: STATIC
  • 3: CRSTATIC

WorkTunnelIfIndex

Index of the tunnel interface

SignalledTunnelName

Tunnel alias.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.12.7.1.3.1.1.3

hwMplsPsWorkTunnName

hwMplsPsIndex

1.3.6.1.4.1.2011.5.25.121.1.1.1.30

hwMplsTunnelSignalProto

hwMplsTunnelIndex

hwMplsTunnelInstance

hwMplsTunnelIngressLSRId

hwMplsTunnelEgressLSRId

1.3.6.1.4.1.2011.5.25.121.1.1.1.33

hwMplsTunnelSignalledTunnelName

hwMplsTunnelIndex

hwMplsTunnelInstance

hwMplsTunnelIngressLSRId

hwMplsTunnelEgressLSRId

Impact on the System

APS is not effected on both ends.

Possible Causes

No APS frame was transmitted on the protect tunnel.

Procedure

1. Run the display mpls te tunnel-interface command and check whether the Tunnel State Desc field is displayed as UP.

  • If so, go to step 2.
  • If not, see "TE Tunnel Is Down".

2. Run the ping lsp te tunnel interface-number command on the ingress of the protection tunnel to check whether traffic runs properly.

  • If so, go to step 3.
  • If not, see "Host Cannot Transmit Packets Along an LSP".

3. Check whether the physical link over which the tunnel is set up is faulty.

  • If so, repair the physical link.
  • If not, go to step 4.

4. Collect the alarm, log, and configuration information, and Collect alarm information and configuration information, and then contact technical support personnel..

5. End.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >