Tunnel protection group did not receive APS frames from protection tunnel. (IfIndex=[WorkTunnelIfIndex], SessionTunnelId=[SessionTunnelId], LocalLspId=[LocalLspId], IngressLsrId=[IngressLsrId], EgressLsrId=[EgressLsrId], WorkTunnel=[WorkTunnel], SignalingProtocol=[SgnlPrtcl], SignalledTunnelName=[SignalledTunnelName])
No APS frame was transmitted on the protect tunnel in the tunnel protection group.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Warning |
Mnemonic Code |
hwMplsApsLost |
Trap OID |
1.3.6.1.4.1.2011.5.12.7.1.4.5 |
MIB |
HUAWEI-MPLSOAM-MIB |
Alarm ID |
0x0001006a |
Alarm Name |
hwMplsApsLost |
Alarm Type |
communicationsAlarm |
Raise or Clear |
Raise |
Match trap |
TUNNEL-TE_1.3.6.1.4.1.2011.5.12.7.1.4.6 hwMplsApsLostRecovery |
Parameter | Description |
---|---|
SessionTunnelId |
Indicates the tunnel ID. |
LocalLspId |
Indicates the local LSP ID. |
IngressLsrId |
Indicates the LSR ID of the ingress node. |
EgressLsrId |
Indicates the LSR ID of the egress node. |
WorkTunnel |
Indicates the name of the working tunnel in the protection group. |
SgnlPrtcl |
Indicates the tunnel protocol ID. The options are as follows:
|
WorkTunnelIfIndex |
Index of the tunnel interface |
SignalledTunnelName |
Tunnel alias. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.12.7.1.3.1.1.3 |
hwMplsPsWorkTunnName |
hwMplsPsIndex |
1.3.6.1.4.1.2011.5.25.121.1.1.1.30 |
hwMplsTunnelSignalProto |
hwMplsTunnelIndex hwMplsTunnelInstance hwMplsTunnelIngressLSRId hwMplsTunnelEgressLSRId |
1.3.6.1.4.1.2011.5.25.121.1.1.1.33 |
hwMplsTunnelSignalledTunnelName |
hwMplsTunnelIndex hwMplsTunnelInstance hwMplsTunnelIngressLSRId hwMplsTunnelEgressLSRId |
1. Run the display mpls te tunnel-interface command and check whether the Tunnel State Desc field is displayed as UP.
2. Run the ping lsp te tunnel interface-number command on the ingress of the protection tunnel to check whether traffic runs properly.
3. Check whether the physical link over which the tunnel is set up is faulty.
4. Collect the alarm, log, and configuration information, and Collect alarm information and configuration information, and then contact technical support personnel..
5. End.