TWAMP_1.3.6.1.4.1.2011.5.25.333.1.4.9 hwTwampSenderSessionNumExceed

Trap Buffer Description

The number of TWAMP sender session is out of device capability.

The number of TWAMP sessions on the session-sender exceeded the device capability.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwTwampSenderSessionNumExceed

Trap OID

1.3.6.1.4.1.2011.5.25.333.1.4.9

MIB

HUAWEI-TWAMP-MIB

Alarm ID

0x00F100c3

Alarm Name

TWAMP_SENDSES_EXCEED

Alarm Type

qualityOfServiceAlarm

Raise or Clear

Raise

Match trap

TWAMP_1.3.6.1.4.1.2011.5.25.333.1.4.10 hwTwampSenderSessionNumRecovery

Trap Buffer Parameters

None

VB Parameters

None

Impact on the System

The excess TWAMP sessions on the session-sender cannot work properly.

Possible Causes

  • Cause 1: The board was reset or became faulty or the board was removed in the case of normal TWAMP session status, causing the number of TWAMP sessions on the session-sender to exceed the device capability.
  • Cause 2: This alarm is generated when the number of TWAMP sender sessions configured on the device exceeds the device capability.
  • Cause 3: This alarm is generated when a link-bundle TWAMP sender session has excessive trunk member interfaces.

Procedure

1.Delete some TWAMP sessions on the TWAMP sender or delete some member interfaces of the link-bundle session or insert new boards to increase the device capability and check whether the alarm is cleared.

  • If the alarm is cleared, the session status on the TWAMP session-sender becomes normal.
  • If the alarm persists, go to Step 2.

2. Collect the alarm, log, and configuration information, and contact Huawei technical support personnel