VXLAN_1.3.6.1.4.1.2011.5.25.40.1.3.2.12 hwCuUpVxlanTunnelDown

Trap Buffer Description

A VXLAN tunnel between the CP and UP Service went Down.(SrcAddr=[SrcAddr], PeerAddr=[PeerAddr], VniId=[VniId], Vpn=[Vpn])

A VXLAN tunnel between the UP and CP went Down.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwCuUpVxlanTunnelDown

Trap OID

1.3.6.1.4.1.2011.5.25.40.1.3.2.12

MIB

HUAWEI-BRAS-SRVCFG-INTERFACE-MIB

Alarm ID

0x00F10259

Alarm Name

hwCuUpVxlanTunnelDown

Alarm Type

communicationsAlarm

Raise or Clear

Raise

Match trap

VXLAN_1.3.6.1.4.1.2011.5.25.40.1.3.2.13 hwCuUpVxlanTunnelResume

Trap Buffer Parameters

Parameter Description

SrcAddr

UP-side IP address of the VXLAN tunnel in the CU separation scenario

PeerAddr

CP-side IP address of the VXLAN tunnel in the CU separation scenario

VniId

VXLAN network identifier

Vpn

UP-side VPN of the VXLAN tunnel in the CU separation scenario

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.40.1.3.1.5

hwCuVxlanTunnelSrcIpAddr

-

1.3.6.1.4.1.2011.5.25.40.1.3.1.6

hwCuVxlanTunnelPeerIpAddr

-

1.3.6.1.4.1.2011.5.25.40.1.3.1.7

hwCuVxlanTunnelInVni

-

1.3.6.1.4.1.2011.5.25.40.1.3.1.8

hwCuVxlanTunnelVpn

-

Impact on the System

The communication between UP and CP fails.

Possible Causes

A VXLAN tunnel between the CP and UP was down in the CU separation scenario.

Procedure

1.Check whether the device is running properly.

  • If the device is running properly, go to Step 3.
  • If the device is running abnormally, restart the device and then go to Step 2.

2.Check whether the trap message is cleared.

  • If the trap message is cleared, go to Step 4.
  • If the trap message persists, go to Step 3.

4. Collect alarm, log, and configuration information, and contact technical support personnel.

5. End.

Copyright © Huawei Technologies Co., Ltd.