BRASAAA_1.3.6.1.4.1.2011.5.2.2.2.0.28 hwPolicyRouteSlotMaxNum

Trap Buffer Description

The number of policy route resources on the board exceeded the threshold.(Slot=[Slot],PolicyRouteThreshold=[PolicyRouteThreshold],CID=[CID],PolicyRoute=[PolicyRoute])

The number of policy routes reached the upper limit on the board.

In VS mode, this trap is supported only by the admin VS.

This alarm is supported only on NetEngine 8000 F1A.

Trap Attributes

Trap Attribute Description

Alarm or Event

Event

Trap Severity

Warning

Mnemonic Code

PROUTE_THRESHOLD

Trap OID

1.3.6.1.4.1.2011.5.2.2.2.0.28

MIB

HUAWEI-AAA-MIB

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Name

This is an event trap and does not involve alarm name.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

-

Trap Buffer Parameters

Parameter Description

Slot

Slot number.

PolicyRouteThreshold

Upper limit.

CID

User ID.

PolicyRoute

Policy route address.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.2.1.15.1.8

hwAccessSlotNo

hwAccessIndex

1.3.6.1.4.1.2011.5.2.2.1.14

hwPolicyRouteThreshold

-

1.3.6.1.4.1.2011.5.2.1.15.1.1

hwAccessIndex

hwAccessIndex

1.3.6.1.4.1.2011.5.2.2.1.15

hwPolicyRoute

-

Impact on the System

If the current number of policy routes reaches 64, new policy routes do not take effect.

Possible Causes

The number of policy routes reached the upper limit on the board.

Procedure

Collect trap, log, and configuration information, and contact technical support personnel.