BRASAAA_1.3.6.1.4.1.2011.5.2.2.2.0.57 hwAAASlotIPv6AddressThresholdAlarm

Trap Buffer Description

The number of ipv6 address in the slot reached the upper limit of the device. (Slot=[slotId],hwAAASlotIpv6AddrThreshold=[threshold])

The number of ipv6 address in the slot reached the upper limit of the device.

In VS mode, this trap is supported only by the admin VS.

This alarm is supported only on NetEngine 8000 F1A.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwAAASlotIPv6AddressThresholdAlarm

Trap OID

1.3.6.1.4.1.2011.5.2.2.2.0.57

MIB

HUAWEI-AAA-MIB

Alarm ID

0x0aeb201b

Alarm Name

hwAAASlotIPv6AddressThresholdAlarm

Alarm Type

qualityOfServiceAlarm

Raise or Clear

Raise

Match trap

BRASAAA_1.3.6.1.4.1.2011.5.2.2.2.0.58 hwAAASlotIPv6AddressThresholdResume

Trap Buffer Parameters

Parameter Description

slotId

ID of the slot through which users go online

threshold

Upper threshold for IPv6 addresses used on the board

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.2.2.1.4

hwUserSlot

-

1.3.6.1.4.1.2011.5.2.2.1.37

hwAAASlotIPv6AddressThreshold

-

Impact on the System

New users cannot go online.

Possible Causes

Cause 1: A large number of users went online, and the number of IPv6 addresses used on the board reached the configured upper threshold.

Cause 2: A small upper threshold was configured.

Procedure

Collect trap, log, and configuration information, and contact technical support personnel.
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >