Inconsistency between application configuration data and master main board configuration data.
The data in the service process database is inconsistent with that in the central database.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Critical |
Mnemonic Code |
APPDATA_NOT_SYN |
Trap OID |
1.3.6.1.4.1.2011.6.10.2.11 |
MIB |
HUAWEI-CONFIG-MAN-MIB |
Alarm ID |
0x08152022 |
Alarm Name |
APPDATA_NOT_SYN |
Alarm Type |
processingErrorAlarm |
Raise or Clear |
Raise |
Match trap |
CONFIGURATION_1.3.6.1.4.1.2011.6.10.2.12 hwCfgAppDataInconsistentResume |
None
None
1. Run the reset slot slot-id command to reset the card in the slot corresponding to the process based on the alarm information to synchronize the data in the service process database. Check whether the alarm is cleared.
2. Collect alarm, log, and configuration information, and contact Huawei technical support personnel.